Industrial Robot Hydraulic Design: Difference between revisions

From Open Source Ecology
Jump to navigation Jump to search
(Added preparation for specifications)
(Added illustrated overview)
Line 1: Line 1:
=Overview=
=Illustrated Overview=
The current plan is to use a parallel hydraulic circuit (constant pressure at each joint motor, varying flow based on load force and extent of valve opening). If so, flow control is necessary (to control speed of arm movement for varying load forces) and directional control is necessary (to allow reverse arm movement). Also, a pressure relief valve back to the tank is necessary to maintain continuity of flow even while all 6 joints are stationary.
The current plan is to use a parallel hydraulic circuit (constant pressure at each joint motor, varying flow based on load force and extent of valve opening). If so, flow control is necessary (to control speed of arm movement for varying load forces) and directional control is necessary (to allow reverse arm movement). Also, a pressure relief valve back to the tank is necessary to maintain continuity of flow even while all 6 joints are stationary.
[[Image:HydRobotOverview.png]]


=Flow Control=
=Flow Control=

Revision as of 23:29, 1 June 2011

Illustrated Overview

The current plan is to use a parallel hydraulic circuit (constant pressure at each joint motor, varying flow based on load force and extent of valve opening). If so, flow control is necessary (to control speed of arm movement for varying load forces) and directional control is necessary (to allow reverse arm movement). Also, a pressure relief valve back to the tank is necessary to maintain continuity of flow even while all 6 joints are stationary.

HydRobotOverview.png

Flow Control

Wikipedia on Needle Valves

Tpub on Needle Valves

Possibility is needle valve operated through a stepper motor which can be electronically controlled.

The flow control valve must be able to permit a flow rate from 0 to X gallons per minute (GPM) and withstand a pressure of X pounds per square inch (psi).

Directional Control

Wikipedia on Solenoid Valves

Hydraulicspenumatics on Hydraulics (including directional valves)

Possibility is 2-position, 4-way solenoid valve.

The directional control valve must be able to permit a flow rate of up to X gallons per minute (GPM) and withstand a pressure of X pounds per square inch (psi).

Pressure Relief

Wikipedia on Pressure Relief Valves

A pressure relief valve can maintain continuity of flow from the pump even while all flow control valves are closed. This improves the safety level of the hydraulic system as pressure buildup can cause failure in a hydraulic component.

Given the characteristics of the powercube used for powering the industrial robot's hydraulic system, the pressure relief valve must be able to handle a flow rate of X gallons per minute (GPM) and activate at a pressure of X pounds per square inch (psi).