CEB Press/User's Manual/Testing: Difference between revisions

From Open Source Ecology
Jump to navigation Jump to search
(Created page with "'''1''' Tools 2 Computer 2 USB Cable 2 CEB Press '''1''' Steps 2 Upload the CEB Testing Code http://opensourceecology.org/wiki/CEB_Press/Manufacturing_Instructions/Code_Upl...")
 
No edit summary
 
(One intermediate revision by the same user not shown)
Line 6: Line 6:


2 CEB Press
2 CEB Press
'''1''' Code
2 CEB Testing Python Code V2 Annotated
http://opensourceecology.org/wiki/File:CEBTesting.txt


'''1''' Steps
'''1''' Steps
Line 17: Line 23:
2 Within the CEB Testing Python GUI (Graphical User Interface), click "open connection". If connection is not established, check that the port name in the Arduino IDE Tools>Serial Port matches the port name within the CEB Testing Code near the beginning.
2 Within the CEB Testing Python GUI (Graphical User Interface), click "open connection". If connection is not established, check that the port name in the Arduino IDE Tools>Serial Port matches the port name within the CEB Testing Code near the beginning.


2 GUI Testing Instructions - Make sure not to jam the cylinder movements.
2 GUI Testing Instructions - For passive testing (without hydraulic power), listen for the solenoid ticks and LED arrows lighting up. For active testing (with hydraulic power), keep the cylinders unjammed.


3
3

Latest revision as of 20:05, 28 December 2011

1 Tools

2 Computer

2 USB Cable

2 CEB Press

1 Code

2 CEB Testing Python Code V2 Annotated

http://opensourceecology.org/wiki/File:CEBTesting.txt

1 Steps

2 Upload the CEB Testing Code

http://opensourceecology.org/wiki/CEB_Press/Manufacturing_Instructions/Code_Upload

2 Run the CEB Testing Python Code

2 Within the CEB Testing Python GUI (Graphical User Interface), click "open connection". If connection is not established, check that the port name in the Arduino IDE Tools>Serial Port matches the port name within the CEB Testing Code near the beginning.

2 GUI Testing Instructions - For passive testing (without hydraulic power), listen for the solenoid ticks and LED arrows lighting up. For active testing (with hydraulic power), keep the cylinders unjammed.

3

MOSFET 3 = Primary Cylinder Down

MOSFET 6 = Primary Cylinder Up

MOSFET 9 = Secondary Cylinder Left

MOSFET 10 = Secondary Cylinder Right

MOSFET 11 = Shaker Spin

LED = Arduino LED

Sensor = All Sensors Are Read at Medium Frequency (check Arduino IDE serial monitor for the observed analog values)

2 Toggle off the controller box to stop the CEB Press electronic influence on the hydraulic system (all solenoids return to open center, all work ports offline).