Hydraulic Cooler Sizing: Difference between revisions
Tom Griffing (talk | contribs) No edit summary |
Tom Griffing (talk | contribs) No edit summary |
||
Line 16: | Line 16: | ||
! Engine hp | ! Engine hp | ||
! Formula | ! Formula | ||
! | ! Horsepower | ||
! BTU/hr | |||
|- | |- | ||
|28 | |28 | ||
|28 * 0.25 * 2542, 28 * 0.3 * 2542 | |28 * 0.25 * 2542, 28 * 0.3 * 2542 | ||
|17794 - 21352 | |7 - 8.4 | ||
|17794 - 21352 | |||
|- | |- | ||
|50 | |50 | ||
|50 * 0.25 * 2542, 50 * 0.3 * 2542 | |50 * 0.25 * 2542, 50 * 0.3 * 2542 | ||
|31775 | |12.5 - 15 | ||
|31775 - 38130 | |||
|} | |} | ||
3. Select a cooler based on the BTU/hr derived in step 1 above. One resource for choosing a cooler is the following page from HaydenAuto.com - in the section "Heavy Duty Oil Coolers": | 3. Select a cooler based on the BTU/hr derived in step 1 above. For the case of the 50 hp Power Cube, search for coolers that dissipate between 31775 and 38130 BTU/hr. One resource for choosing a cooler is the following page from HaydenAuto.com - in the section "Heavy Duty Oil Coolers": | ||
http://www.haydenauto.com/upload/HaydenAuto/Documents/Cat_Hayden/2007-hayden-trans-oil-coolers.pdf | http://www.haydenauto.com/upload/HaydenAuto/Documents/Cat_Hayden/2007-hayden-trans-oil-coolers.pdf | ||
Note: The "COOLING BTU / HR" ratings is with 2500 cubic-ft/min airflow and 100°F differential in oil and air temperatures. So, this requires a fan to move the air to meet these requirements. | Note: The "COOLING BTU / HR" ratings is with 2500 cubic-ft/min airflow and 100°F differential in oil and air temperatures. So, this requires a fan to move the air to meet these requirements. |
Revision as of 19:01, 28 April 2013
This page describes how to size a hydraulic oil cooler for a hydraulic system. Hydraulic coolers are often specified by their ability to dissipate heat - usually measured in BTU/hr.
1. The power in the hydraulic system:
Horsepower = Pressure * Flow / 1714
2. The heat dissipated in a hydraulic system can be determined by summing the inefficiencies of all components in the system, but is usually between 25% adn 30%. The heat dissipated is measured in BTU/hr:
Heat dissipated = Horsepower * 0.3 * 2542
Here are some calculations for OSE engines:
Engine hp | Formula | Horsepower | BTU/hr |
---|---|---|---|
28 | 28 * 0.25 * 2542, 28 * 0.3 * 2542 | 7 - 8.4 | 17794 - 21352 |
50 | 50 * 0.25 * 2542, 50 * 0.3 * 2542 | 12.5 - 15 | 31775 - 38130 |
3. Select a cooler based on the BTU/hr derived in step 1 above. For the case of the 50 hp Power Cube, search for coolers that dissipate between 31775 and 38130 BTU/hr. One resource for choosing a cooler is the following page from HaydenAuto.com - in the section "Heavy Duty Oil Coolers":
http://www.haydenauto.com/upload/HaydenAuto/Documents/Cat_Hayden/2007-hayden-trans-oil-coolers.pdf
Note: The "COOLING BTU / HR" ratings is with 2500 cubic-ft/min airflow and 100°F differential in oil and air temperatures. So, this requires a fan to move the air to meet these requirements.