Hydraulic Hose Sizing: Difference between revisions

From Open Source Ecology
Jump to navigation Jump to search
No edit summary
No edit summary
Line 41: Line 41:


Both Pressure and Return hose sizes should be increased to 3/4", as well as all couplers and fittings.
Both Pressure and Return hose sizes should be increased to 3/4", as well as all couplers and fittings.
[[Category:Power Cube]]

Revision as of 01:48, 16 August 2011

Hydraulic Hose Sizing

The size of the suction hose for the power cube, it is calculated from the fluid velocity in the hose. The general values used are:

Pressure: 20 ft/sec
Return: 15 ft/sec
Suction: 5 ft/sec


The formula for calculating the hose size is as follows:

V = Q / (3.117 * pi/4 * D ^ 2)

or

D = (Q / (3.117 * pi/4 * V) ) ^ 1/2

Where:

V is fluid velocity in ft/sec
Q is fluid volume in gallons/min
D is hose inside diameter in inches


In the case of the Power Cube suction hose, V = 5 ft / sec and the Q is approximately 13 GPM, so:

D = (13 GPM / (3.117 * pi/4 * 5 ft/sec) ) ^ 1/2 = 1.03 in


The sizing guidelines say to always round up - meaning take the next size larger than 1.03 inches (probably 1 1/4").

While I thought the sizing for the pressure lines was OK, I double-checked and found the formula indicates that the supply and return hoses should be larger as well:

D = (13 GPM / (3.117 * pi/4 * 20 ft/sec) ) ^ 1/2 = 0.515 in


Also, the return lines appear to be undersized as well:

D = (13 / (3.117 * pi/4 * 15 ft/sec) ) ^ 1/2 = 0.595 in

Both Pressure and Return hose sizes should be increased to 3/4", as well as all couplers and fittings.