Compressed Air Water Pump: Difference between revisions
Jump to navigation
Jump to search
Line 12: | Line 12: | ||
=Design 1= | =Design 1= | ||
*2" PVC pipe | ==BOM== | ||
*2' x 2" PVC pipe | |||
[http://www.plumbingsupply.com/pvc.html#plug] | *2" flat PVC cap | ||
[[Image:plug.jpg|thumb]] | *2" Spigot x 3/4" Fips [http://www.plumbingsupply.com/pvc.html#plug] [[Image:plug.jpg|thumb]] | ||
*3/4" male thread coupling | |||
*3/4" metal check valve | |||
*2 x 3/4" male threaded PVC plugs | |||
*2' x 3/4" PVC pipe | |||
*2 x 3/4" hoses long enough to go down the well | |||
==Construction== | |||
#Ream out one 3/4" male threaded PVC plug with a 3/4" hole for the 2' x 3/4" pipe and attach them. | |||
#Drill two 5/8" holes in the flat PVC cap and tap them to 3/4" for the air in and water out 3/4" male threaded PVC plugs. Use plumbers tape and attach the plugs. Glue the PVC cap to the 2' x 2" pipe. | |||
#Remove the spring of the metal check valve like in the hydromissions slapshot instructions. | |||
#Glue the 2" to 3/4" plug to the other end of the 2' x 2" pipe, attach the 3/4" male threaded coupler and the 3/4" check valve. | |||
#Attach the hoses to the plugs with plumbers tape and clamps and test the pump. | |||
[[Category:Water Well]] | [[Category:Water Well]] |
Revision as of 18:25, 8 June 2009
Research
http://www.hydromissions.com/products.htm http://www.hydromissions.com/slapshotconstruction.pdf
From http://www.airwellpumps.com/HowDoesItWork.aspx :
Design 1
BOM
- 2' x 2" PVC pipe
- 2" flat PVC cap
- 2" Spigot x 3/4" Fips [1]
- 3/4" male thread coupling
- 3/4" metal check valve
- 2 x 3/4" male threaded PVC plugs
- 2' x 3/4" PVC pipe
- 2 x 3/4" hoses long enough to go down the well
Construction
- Ream out one 3/4" male threaded PVC plug with a 3/4" hole for the 2' x 3/4" pipe and attach them.
- Drill two 5/8" holes in the flat PVC cap and tap them to 3/4" for the air in and water out 3/4" male threaded PVC plugs. Use plumbers tape and attach the plugs. Glue the PVC cap to the 2' x 2" pipe.
- Remove the spring of the metal check valve like in the hydromissions slapshot instructions.
- Glue the 2" to 3/4" plug to the other end of the 2' x 2" pipe, attach the 3/4" male threaded coupler and the 3/4" check valve.
- Attach the hoses to the plugs with plumbers tape and clamps and test the pump.