Industrial Robot Hydraulic Design: Difference between revisions

From Open Source Ecology
Jump to navigation Jump to search
m (→‎Illustrated Overview: Edited for clarity)
(Added component examples)
Line 13: Line 13:


The flow control valve must be able to permit a flow rate from 0 to X gallons per minute (GPM) and withstand a pressure of X pounds per square inch (psi).  
The flow control valve must be able to permit a flow rate from 0 to X gallons per minute (GPM) and withstand a pressure of X pounds per square inch (psi).  
[http://www.surpluscenter.com/item.asp?item=9-5302-50&catname=hydraulic Needle Valve Example]


=Directional Control=
=Directional Control=
Line 23: Line 25:


The directional control valve must be able to permit a flow rate of up to X gallons per minute (GPM) and withstand a pressure of X pounds per square inch (psi).
The directional control valve must be able to permit a flow rate of up to X gallons per minute (GPM) and withstand a pressure of X pounds per square inch (psi).
[http://www.surpluscenter.com/item.asp?item=9-7748&catname=hydraulic 2-position Solenoid Valve Example]


=Pressure Relief=
=Pressure Relief=
Line 31: Line 35:


Given the characteristics of the powercube used for powering the industrial robot's hydraulic system, the pressure relief valve must be able to handle a flow rate of X gallons per minute (GPM) and activate at a pressure of X pounds per square inch (psi).
Given the characteristics of the powercube used for powering the industrial robot's hydraulic system, the pressure relief valve must be able to handle a flow rate of X gallons per minute (GPM) and activate at a pressure of X pounds per square inch (psi).
[http://www.surpluscenter.com/item.asp?item=9-6135-50-H&catname=hydraulic Pressure Relief Valve Example]


[[Category: Industrial Robot]]
[[Category: Industrial Robot]]

Revision as of 14:08, 5 June 2011

Illustrated Overview

The current plan is to use a parallel hydraulic circuit (constant pressure at each joint motor, varying flow based on load force and extent of valve opening). If so, flow control is necessary (to control speed of arm movement for varying load forces) and directional control is necessary (to allow reverse arm movement). Also, a pressure relief valve back to the tank is necessary to maintain continuity of flow even while all 6 joints are stationary. Below, the arrows represent hydraulic hose connections.

HydRobotOverview.png

Flow Control

Wikipedia on Needle Valves

Tpub on Needle Valves

Possibility is needle valve operated through a stepper motor which can be electronically controlled.

The flow control valve must be able to permit a flow rate from 0 to X gallons per minute (GPM) and withstand a pressure of X pounds per square inch (psi).

Needle Valve Example

Directional Control

Wikipedia on Solenoid Valves

Hydraulicspenumatics on Hydraulics (including directional valves)

Possibility is 2-position, 4-way solenoid valve.

The directional control valve must be able to permit a flow rate of up to X gallons per minute (GPM) and withstand a pressure of X pounds per square inch (psi).

2-position Solenoid Valve Example

Pressure Relief

Wikipedia on Pressure Relief Valves

A pressure relief valve can maintain continuity of flow from the pump even while all flow control valves are closed. This improves the safety level of the hydraulic system as pressure buildup can cause failure in a hydraulic component.

Given the characteristics of the powercube used for powering the industrial robot's hydraulic system, the pressure relief valve must be able to handle a flow rate of X gallons per minute (GPM) and activate at a pressure of X pounds per square inch (psi).

Pressure Relief Valve Example