CEB Press/Manufacturing Instructions/Sensor Unit
Main > Housing and construction > CEB Press > CEB press building instructions
Tools
- Soldering Iron
- Soldering Stand
- Solder
- Wet sponge or wet paper towel
- Heat Gun
- 22AWG-compatible Wire Stripper
Materials
- Hall Effect Sensor
- PVC Pipe with 1/2" Thickness, 5/8" Outer Diameter, 3.5" Length
- Underground telephone cable (4 wire)
- 2-part Potting Compound
- Disposable Mixing Cups
- Shrink Wrap
- potting compound
- disposable mixing cups
- tape
- cat5 cable
- shrink wrap
Diagrams
Fabrication Steps
Sensor Construction
A four wire telephone cable is used to connect to the hall effects sensor. Only three of the exposed wires are used; orange, blue/white, and blue. These wires are soldered to the three prongs of the hall effects sensor in order from left to right when the hall effect sensor orientation includes visible text and the prongs pointing downwards: blue, orange, blue-white. Small shrink wrap should be applied to the wires prior to soldering, and then slid into place to cover the leads to prevent short circuiting.
Slide the sensor into a small piece of pvc tube 3.5 inches long. The pvc will be filled with a potting compound to encapsulate the sensor. Tightly wrap electrical tape around the wire exiting the pvc tube, creating a seal to hold in the potting compound. Clamp the pvc vertically with the wire protruding from the bottom and fill the inside of the pvc with the potting compound.
- cut telephone cable 70" long
- strip shielding plastic 1.5" and 8" at either end
- solder hall effects sensor
Step 2. Take one Hall Effect sensor.
Fabricate the Sensors
- Cut three 3’ sections of Underground Telephone Cable.
- Strip about 3” of the outer covering off each end of the three sections
- Strip about ¼” off the orange, blue and blue-white wires at each end of each section.
- Tin the ends of the all of the wires on all of the sections
- Splice, with Solder, about 6” of the inner strands of some Cat-5 Cable (E17) to the wires at one end of each of the sections of Underground Telephone Cable
- Thread shrink-wrap (E28) to the three wires on the other end of each of the three sections of Underground Telephone Cable.
- Solder a Hall Effect Sensor (E20) to one endof the ther sections (pins numbered from left to right)
- Pin 1: Blue (5V)
- Pin 2: Orange (GND)
- Pin 3: Blue-White (Signal)
- Shrink the Shrink-Wrap around each of the solder joints
- Cut three 3.5” sections of PVC Pipe (E15).
- Place a section of Pipe around each of the three hall effect sensors and encase them in Potting Compound (E29) with the Pipe Caps (E16) in place.