MicroHouse Interior Walls: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
=Requirement= | =Requirement= | ||
*Test-driven Contract-First Requirement - flat surface for meeting with other wall or brick sections | *Test-driven Contract-First Requirement - flat surface for meeting with other wall or brick sections | ||
*Detachable with fasteners that | *Detachable with exposed fasteners that can be accessed for deconstruction | ||
*Caulked at seams if necessary | *Caulked at right angle seams if necessary | ||
*Allow for slanted sections | *Fully insulated air tight when joining adjacent panels | ||
*Allow for slanted sections under roof | |||
*R19 - ex [http://www.menards.com/main/building-materials/insulation/rolls-batts/6-1-4-t-x-23-w-x-93-l-r-19-kraft-faced-fiberglass-batts/p-1729444-c-5780.htm] | *R19 - ex [http://www.menards.com/main/building-materials/insulation/rolls-batts/6-1-4-t-x-23-w-x-93-l-r-19-kraft-faced-fiberglass-batts/p-1729444-c-5780.htm] | ||
*Uses 2"x6" lumber, integrating with 2"x6" being used for all other structural components. | *Uses 2"x6" lumber, integrating with 2"x6" being used for all other structural components. | ||
*Layers 2 framed sections to achieve any width necessary, such as 15" | *Layers 2 framed sections to achieve any width necessary, such as 15" | ||
*Fittable with brick interior | |||
*Standard panel size of 4'x8', though 4'x7" in the present case due to lower ceiling height | |||
*Integrate with outer wood walls in that outer walls involve doubling + spacing of inner wall panels | |||
* | |||
=Concept + Instructional= | =Concept + Instructional= | ||
<html></html> | <html></html> |
Revision as of 00:48, 4 September 2014
Requirement
- Test-driven Contract-First Requirement - flat surface for meeting with other wall or brick sections
- Detachable with exposed fasteners that can be accessed for deconstruction
- Caulked at right angle seams if necessary
- Fully insulated air tight when joining adjacent panels
- Allow for slanted sections under roof
- R19 - ex [1]
- Uses 2"x6" lumber, integrating with 2"x6" being used for all other structural components.
- Layers 2 framed sections to achieve any width necessary, such as 15"
- Fittable with brick interior
- Standard panel size of 4'x8', though 4'x7" in the present case due to lower ceiling height
- Integrate with outer wood walls in that outer walls involve doubling + spacing of inner wall panels
Concept + Instructional