=Requirement= | =Requirement= | ||
*Test-driven Contract-First Requirement - flat surface for meeting with other wall or brick sections | *Test-driven Contract-First Requirement - flat surface for meeting with other wall or brick sections | ||
*3/8" plywood face, painted on outside | |||
*Detachable with exposed fasteners that can be accessed for deconstruction | *Detachable with exposed fasteners that can be accessed for deconstruction | ||
*Caulked at right angle seams if necessary | *Caulked at right angle seams if necessary | ||
Line 11: | Line 12: | ||
*Standard panel size of 4'x8', though 4'x7" in the present case due to lower ceiling height | *Standard panel size of 4'x8', though 4'x7" in the present case due to lower ceiling height | ||
*Integrate with outer wood walls in that outer walls involve doubling + spacing of inner wall panels | *Integrate with outer wood walls in that outer walls involve doubling + spacing of inner wall panels | ||
* | *Applicable in nature to inner and outer walls. | ||
*Integrated via flat face to window and door panels. | |||
*One side is finished and painted upon install. Insulation inside, and second side is open. Closing panel is pre-painted. | |||
*Straightness is enforced via plywood edge | |||
=Concept + Instructional= | =Concept + Instructional= | ||
<html></html> | <html></html> |
Revision as of 00:54, 4 September 2014
Requirement
- Test-driven Contract-First Requirement - flat surface for meeting with other wall or brick sections
- 3/8" plywood face, painted on outside
- Detachable with exposed fasteners that can be accessed for deconstruction
- Caulked at right angle seams if necessary
- Fully insulated air tight when joining adjacent panels
- Allow for slanted sections under roof
- Uses R19 fiberglass batts - ex [1]
- Uses 2"x6" lumber, integrating with 2"x6" being used for all other structural components.
- Layers 2 framed sections to achieve any width necessary, such as 15" for exterior wall.
- Fittable with brick interior
- Standard panel size of 4'x8', though 4'x7" in the present case due to lower ceiling height
- Integrate with outer wood walls in that outer walls involve doubling + spacing of inner wall panels
- Applicable in nature to inner and outer walls.
- Integrated via flat face to window and door panels.
- One side is finished and painted upon install. Insulation inside, and second side is open. Closing panel is pre-painted.
- Straightness is enforced via plywood edge
Concept + Instructional