MicroHouse Interior Walls: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 22: | Line 22: | ||
*Stackable in height | *Stackable in height | ||
*Extensiblle in lenght via layering | *Extensiblle in lenght via layering | ||
*Allow for ready addition of modules without having to redo surface finish - by having a flat edge surface, and creating a flat face. | |||
=Concept + Instructional= | =Concept + Instructional= | ||
<html><iframe src="https://docs.google.com/presentation/d/1IlFKPJ7JPKsOfZ9Vtd_5CefZa9wA-v_vj4iuQ2Lbdd0/embed?start=false&loop=false&delayms=3000" frameborder="0" width="960" height="569" allowfullscreen="true" mozallowfullscreen="true" webkitallowfullscreen="true"></iframe></html> | <html><iframe src="https://docs.google.com/presentation/d/1IlFKPJ7JPKsOfZ9Vtd_5CefZa9wA-v_vj4iuQ2Lbdd0/embed?start=false&loop=false&delayms=3000" frameborder="0" width="960" height="569" allowfullscreen="true" mozallowfullscreen="true" webkitallowfullscreen="true"></iframe></html> |
Revision as of 13:45, 4 September 2014
Requirement
- Test-driven Contract-First Requirement - flat surface for meeting with other wall or brick sections
- Usable as exterior walls
- Usable with any size window of 42"x90" or smaller frame
- Usable as a wall unit (exterior or interior), bookshelf, window, or door unit
- 3/8" plywood face, painted on outside
- Detachable with exposed fasteners that can be accessed for deconstruction
- Caulked at right angle seams if necessary
- Fully insulated air tight when joining adjacent panels
- Allow for slanted sections under roof
- Uses R19 fiberglass batts - ex [1]
- Uses 2"x6" lumber, integrating with 2"x6" being used for all other structural components.
- Layers 2 framed sections to achieve any width necessary, such as 15" for exterior wall.
- Fittable with brick interior
- Standard panel size of 4'x8', though 4'x7" in the present case due to lower ceiling height
- Integrate with outer wood walls in that outer walls involve doubling + spacing of inner wall panels
- Applicable in nature to inner and outer walls.
- Integrated via flat face to window and door panels.
- One side is finished and painted upon install. Insulation inside, and second side is open. Closing panel is pre-painted.
- Straightness is enforced via plywood edge
- Extensible in thickness via spacing and larger plywood
- Stackable in height
- Extensiblle in lenght via layering
- Allow for ready addition of modules without having to redo surface finish - by having a flat edge surface, and creating a flat face.
Concept + Instructional