- Initial pump used - .92 cu in as in BOM - for 1950 max PSI and 14 gpm
- To achieve 3000 PSI, a ~9 gpm pump is needed if the engine is 16 hp.
- This .61 cu in pump [1] has 8.8 gpm flow and requires 15.5 hp to drive according to Hydraulic Calculations