Nichrome Wire Calculator: Difference between revisions

From Open Source Ecology
Jump to navigation Jump to search
Line 18: Line 18:
*Note that Gauge 17 is the max fatness that stays within 1800W
*Note that Gauge 17 is the max fatness that stays within 1800W
*Note: 22' of 18 ga gets us right at 120V, and 1560W. Good.
*Note: 22' of 18 ga gets us right at 120V, and 1560W. Good.
[[File:nichrome2.png]]


=Examples=
=Examples=

Revision as of 20:10, 25 November 2019

Procedure

  • Select convenient length
  • Select max temp - such as 550C = 1000F
  • Match gauge to proper voltage drop of 120V
  • Find out max gauge that is within current limits (15A) and has correct voltage
  • Limit for 15A outlet is 1800W

Sample:

Samplenichrome.png

  • Remains within 15 amps
  • Shows correct voltage
  • Max temp - select it to match voltage - you determine max possible temp and judge whether it will burn out your system if you have temperature sensitive components
  • Note that Gauge 17 is the max fatness that stays within 1800W
  • Note: 22' of 18 ga gets us right at 120V, and 1560W. Good.

Nichrome2.png

Examples

  • 10m of 22 ga wire will draw 370W at 120V - to attain a temperature of 500F. This may be a good 12" heat bed.
  • 15' of 24 ga wire will draw

Links