Open Source Solar Water Heater: Difference between revisions

From Open Source Ecology
Jump to navigation Jump to search
(Created Page + Added Basic Sections/Info)
 
(Added some more information)
 
(7 intermediate revisions by the same user not shown)
Line 3: Line 3:
*Can be used from cold to near boiling (see [[Open Source Solar Steam Generator]] ) for water to [[Wet Steam]], and [[Open Source Steam Superheater]] for [[Wet Steam]] to [[Dry Steam]]
*Can be used from cold to near boiling (see [[Open Source Solar Steam Generator]] ) for water to [[Wet Steam]], and [[Open Source Steam Superheater]] for [[Wet Steam]] to [[Dry Steam]]
*There are many ways of doing this but this page will focus on pancake coil type designs, see [[Open Source Thermosyphon]] for thermosyphon designs
*There are many ways of doing this but this page will focus on pancake coil type designs, see [[Open Source Thermosyphon]] for thermosyphon designs
*This page may use tube/trough designs, but pancake seems like the main one as of now
*Pancake works well, a tube with modular screw in ports for long plastic tube runs is better for high flow
*Need to look into if these can be grouped for boiling temperatures (this may lead to [[Steam Hammer]] and/or overpressure explosions, but perhaps with the right precautions (Steam traps, overpressure valves. etc)
*Need to look into if these can be grouped for boiling temperatures (this may lead to [[Steam Hammer]] and/or overpressure explosions, but perhaps with the right precautions (Steam traps, overpressure valves. etc)
*Direct systems can be used for pool/utility water, for potable water, indirect may be better
*Hard part seems to be storage systems for the pressurised, potable water
*Some way to make a sort of "on demand hot water" for central hot warer, via indirect heating?
*If not simplest market is pool heating


=Industry Standards=
=Industry Standards=
*
==Plastic Tube Panel==
*[https://www.amazon.com/SolarPoolSupply-Solar-Pool-Heater-Replacement/dp/B076B75D7P/ref=sr_1_1_sspa?dchild=1&keywords=SOLARPOOLSUPPLY&qid=1595969118&sr=8-1-spons&spLa=ZW5jcnlwdGVkUXVhbGlmaWVyPUExWkRVVk9MREk0OVowJmVuY3J5cHRlZElkPUEwOTYxNjEzM0dLWFRCV0w3ODk5VSZlbmNyeXB0ZWRBZElkPUEwMDU4MTk5RUhQMk5SV0ZZRVBEJndpZGdldE5hbWU9c3BfYXRmJmFjdGlvbj1jbGlja1JlZGlyZWN0JmRvTm90TG9nQ2xpY2s9dHJ1ZQ&th=1 A Common Panel Design] ~350 USD minimum


=Existing Open Source Designs=
=Existing Open Source Designs=
==Plastic Tube Coil==
*[https://www.youtube.com/watch?v=btQtPQpUf90 This Design by the Youtube Channel "Dessertsun02" ]  Uses a copper coil with a metal reflector behind it, and a wood frame
*[https://www.youtube.com/watch?v=btQtPQpUf90 This Design by the Youtube Channel "Dessertsun02" ]  Uses a copper coil with a metal reflector behind it, and a wood frame


Line 20: Line 26:


=Basic Design=
=Basic Design=
==Box==
==Plastic Tube Coil==
===Box===
*A wood or metal box
*A wood or metal box
*Optional insulation
*Optional insulation


==Backplate==
===Backplate===
*Sheet metal
*=Sheet metal
*make reflective or dark as well?
*make reflective or dark as well?


=Coil=
===Coil===
*Standard OTS refrigeration coil, or custom bent tubing
*Standard OTS refrigeration coil, or custom bent tubing
*Has the standard fittings at each end
*Has the standard fittings at each end


=Insulation=
===Insulation===
*Foam and/or fiber for the main areas
*Foam and/or fiber for the main areas
*Glass and air/vacuum gap above coil, or would the walls and cost make it not worth it?
*Glass and air/vacuum gap above coil, or would the walls and cost make it not worth it?


=Temperature Probes=
===Temperature Probes===
*Attach right above the hose adapters
*Attach right above the hose adapters
*Wires go where?
*Wires go where?


=Paint=
===Paint===
*Most likely standard black paint, but the darker, the better
*Most likely standard black paint, but the darker, the better
*Not 100% needed, but is a cheap way to increase absorbtion
*Not 100% needed, but is a cheap way to increase absorbtion


=Heat Exchanger?=
===Heat Exchanger?===
*[[Open Source Liquid-Liquid Heat Exchanger]]
*[[Open Source Liquid-Liquid Heat Exchanger]]


=BOM=
===BOM===
*~1m Sheet Metal (what metal?)
*~1m Sheet Metal (what metal?)
*Fiberglass insulation
*Fiberglass insulation
Line 56: Line 63:
*Perhaps Wood or Plastic Exterior
*Perhaps Wood or Plastic Exterior


=See Also=
==Plastic Tube Panel==
===Rigid High Temp PVC Pipe===
*Used for the top and bottom pipes (ie feed and return)
 
===Flexible (Black) High Temp Hosing===
*Used to get up and down from the panel, and for the panel's "runs"
 
===Attachment Points===
*Either OTS fittings, or some custom solution
*Screw in/otherwise attach to the top and bottom pvc pipes, holding the runs in place, and connecting them to the system
*Modular, as as many as wanted can be added to a cut section of HT PVC Pipe
 
===Control Box===
*Arduino and/or Rpi
*Takes Sensor Data, and IO Settings in
*Controls the Pump
 
===Temperature Probe===
*1 at each end of the collector panel (two total)
*1 in the working fluid tank
*1 at each end of the tank (ie to and from panel)
 
===Pump===
*Small electric pump (calculate head needed)
 
===Working Fluid===
*Most likely some sort of oil (higher viscosity, but will not freeze?
*Also stores heat better
 
=Internal Links=
*
*


=Useful Links=
=External Links=
*
*[https://en.wikipedia.org/wiki/Solar_water_heating The Wikipedia Page on Solar Water Heaters]
*[https://www.energy.gov/energysaver/solar-water-heaters/heat-transfer-fluids-solar-water-heating-systems An Energy.gov page on Working Fluids for Indirect Systems]
*[

Latest revision as of 21:15, 28 July 2020

Basics

  • A Device that uses Solar Thermal to heat water
  • Can be used from cold to near boiling (see Open Source Solar Steam Generator ) for water to Wet Steam, and Open Source Steam Superheater for Wet Steam to Dry Steam
  • There are many ways of doing this but this page will focus on pancake coil type designs, see Open Source Thermosyphon for thermosyphon designs
  • Pancake works well, a tube with modular screw in ports for long plastic tube runs is better for high flow
  • Need to look into if these can be grouped for boiling temperatures (this may lead to Steam Hammer and/or overpressure explosions, but perhaps with the right precautions (Steam traps, overpressure valves. etc)
  • Direct systems can be used for pool/utility water, for potable water, indirect may be better
  • Hard part seems to be storage systems for the pressurised, potable water
  • Some way to make a sort of "on demand hot water" for central hot warer, via indirect heating?
  • If not simplest market is pool heating

Industry Standards

Plastic Tube Panel

Existing Open Source Designs

Plastic Tube Coil

Minimum Viable Product

  • Should be able to reach near boiling (~80C is what most existing designs could reach in one stage)
  • Should be a small flat square (less than 1m^2 wide, and less than 5 cm deep?)
  • Should use standard hose fittings for both the "in" and the "out"
  • Optional temperature probes
  • perhaps have a thicker and slightly wider model with insulation

Basic Design

Plastic Tube Coil

Box

  • A wood or metal box
  • Optional insulation

Backplate

  • =Sheet metal
  • make reflective or dark as well?

Coil

  • Standard OTS refrigeration coil, or custom bent tubing
  • Has the standard fittings at each end

Insulation

  • Foam and/or fiber for the main areas
  • Glass and air/vacuum gap above coil, or would the walls and cost make it not worth it?

Temperature Probes

  • Attach right above the hose adapters
  • Wires go where?

Paint

  • Most likely standard black paint, but the darker, the better
  • Not 100% needed, but is a cheap way to increase absorbtion

Heat Exchanger?

BOM

  • ~1m Sheet Metal (what metal?)
  • Fiberglass insulation
  • Foam Insulation
  • Either copper piping, or an OTS refrigeration coil
  • Fittings
  • Optional temperature sensors
  • Perhaps Wood or Plastic Exterior

Plastic Tube Panel

Rigid High Temp PVC Pipe

  • Used for the top and bottom pipes (ie feed and return)

Flexible (Black) High Temp Hosing

  • Used to get up and down from the panel, and for the panel's "runs"

Attachment Points

  • Either OTS fittings, or some custom solution
  • Screw in/otherwise attach to the top and bottom pvc pipes, holding the runs in place, and connecting them to the system
  • Modular, as as many as wanted can be added to a cut section of HT PVC Pipe

Control Box

  • Arduino and/or Rpi
  • Takes Sensor Data, and IO Settings in
  • Controls the Pump

Temperature Probe

  • 1 at each end of the collector panel (two total)
  • 1 in the working fluid tank
  • 1 at each end of the tank (ie to and from panel)

Pump

  • Small electric pump (calculate head needed)

Working Fluid

  • Most likely some sort of oil (higher viscosity, but will not freeze?
  • Also stores heat better

Internal Links

External Links