Open Source Solar Water Heater: Difference between revisions

From Open Source Ecology
Jump to navigation Jump to search
(Minor Text Formating Fix)
(Added some more information)
 
(One intermediate revision by the same user not shown)
Line 6: Line 6:
*Need to look into if these can be grouped for boiling temperatures (this may lead to [[Steam Hammer]] and/or overpressure explosions, but perhaps with the right precautions (Steam traps, overpressure valves. etc)
*Need to look into if these can be grouped for boiling temperatures (this may lead to [[Steam Hammer]] and/or overpressure explosions, but perhaps with the right precautions (Steam traps, overpressure valves. etc)
*Direct systems can be used for pool/utility water, for potable water, indirect may be better
*Direct systems can be used for pool/utility water, for potable water, indirect may be better
*Hard part seems to be storage systems for the pressurised, potable water
*Some way to make a sort of "on demand hot water" for central hot warer, via indirect heating?
*If not simplest market is pool heating


=Industry Standards=
=Industry Standards=
Line 23: Line 26:


=Basic Design=
=Basic Design=
===Plastic Tube Coil===
==Plastic Tube Coil==
====Box====
===Box===
*A wood or metal box
*A wood or metal box
*Optional insulation
*Optional insulation


====Backplate====
===Backplate===
*=Sheet metal
*=Sheet metal
*make reflective or dark as well?
*make reflective or dark as well?


====Coil====
===Coil===
*Standard OTS refrigeration coil, or custom bent tubing
*Standard OTS refrigeration coil, or custom bent tubing
*Has the standard fittings at each end
*Has the standard fittings at each end


====Insulation====
===Insulation===
*Foam and/or fiber for the main areas
*Foam and/or fiber for the main areas
*Glass and air/vacuum gap above coil, or would the walls and cost make it not worth it?
*Glass and air/vacuum gap above coil, or would the walls and cost make it not worth it?


====Temperature Probes====
===Temperature Probes===
*Attach right above the hose adapters
*Attach right above the hose adapters
*Wires go where?
*Wires go where?


====Paint====
===Paint===
*Most likely standard black paint, but the darker, the better
*Most likely standard black paint, but the darker, the better
*Not 100% needed, but is a cheap way to increase absorbtion
*Not 100% needed, but is a cheap way to increase absorbtion


====Heat Exchanger?====
===Heat Exchanger?===
*[[Open Source Liquid-Liquid Heat Exchanger]]
*[[Open Source Liquid-Liquid Heat Exchanger]]


=====BOM=====
===BOM===
*~1m Sheet Metal (what metal?)
*~1m Sheet Metal (what metal?)
*Fiberglass insulation
*Fiberglass insulation
Line 59: Line 62:
*Optional temperature sensors
*Optional temperature sensors
*Perhaps Wood or Plastic Exterior
*Perhaps Wood or Plastic Exterior
==Plastic Tube Panel==
===Rigid High Temp PVC Pipe===
*Used for the top and bottom pipes (ie feed and return)
===Flexible (Black) High Temp Hosing===
*Used to get up and down from the panel, and for the panel's "runs"
===Attachment Points===
*Either OTS fittings, or some custom solution
*Screw in/otherwise attach to the top and bottom pvc pipes, holding the runs in place, and connecting them to the system
*Modular, as as many as wanted can be added to a cut section of HT PVC Pipe
===Control Box===
*Arduino and/or Rpi
*Takes Sensor Data, and IO Settings in
*Controls the Pump
===Temperature Probe===
*1 at each end of the collector panel (two total)
*1 in the working fluid tank
*1 at each end of the tank (ie to and from panel)
===Pump===
*Small electric pump (calculate head needed)
===Working Fluid===
*Most likely some sort of oil (higher viscosity, but will not freeze?
*Also stores heat better


=Internal Links=
=Internal Links=

Latest revision as of 21:15, 28 July 2020

Basics

  • A Device that uses Solar Thermal to heat water
  • Can be used from cold to near boiling (see Open Source Solar Steam Generator ) for water to Wet Steam, and Open Source Steam Superheater for Wet Steam to Dry Steam
  • There are many ways of doing this but this page will focus on pancake coil type designs, see Open Source Thermosyphon for thermosyphon designs
  • Pancake works well, a tube with modular screw in ports for long plastic tube runs is better for high flow
  • Need to look into if these can be grouped for boiling temperatures (this may lead to Steam Hammer and/or overpressure explosions, but perhaps with the right precautions (Steam traps, overpressure valves. etc)
  • Direct systems can be used for pool/utility water, for potable water, indirect may be better
  • Hard part seems to be storage systems for the pressurised, potable water
  • Some way to make a sort of "on demand hot water" for central hot warer, via indirect heating?
  • If not simplest market is pool heating

Industry Standards

Plastic Tube Panel

Existing Open Source Designs

Plastic Tube Coil

Minimum Viable Product

  • Should be able to reach near boiling (~80C is what most existing designs could reach in one stage)
  • Should be a small flat square (less than 1m^2 wide, and less than 5 cm deep?)
  • Should use standard hose fittings for both the "in" and the "out"
  • Optional temperature probes
  • perhaps have a thicker and slightly wider model with insulation

Basic Design

Plastic Tube Coil

Box

  • A wood or metal box
  • Optional insulation

Backplate

  • =Sheet metal
  • make reflective or dark as well?

Coil

  • Standard OTS refrigeration coil, or custom bent tubing
  • Has the standard fittings at each end

Insulation

  • Foam and/or fiber for the main areas
  • Glass and air/vacuum gap above coil, or would the walls and cost make it not worth it?

Temperature Probes

  • Attach right above the hose adapters
  • Wires go where?

Paint

  • Most likely standard black paint, but the darker, the better
  • Not 100% needed, but is a cheap way to increase absorbtion

Heat Exchanger?

BOM

  • ~1m Sheet Metal (what metal?)
  • Fiberglass insulation
  • Foam Insulation
  • Either copper piping, or an OTS refrigeration coil
  • Fittings
  • Optional temperature sensors
  • Perhaps Wood or Plastic Exterior

Plastic Tube Panel

Rigid High Temp PVC Pipe

  • Used for the top and bottom pipes (ie feed and return)

Flexible (Black) High Temp Hosing

  • Used to get up and down from the panel, and for the panel's "runs"

Attachment Points

  • Either OTS fittings, or some custom solution
  • Screw in/otherwise attach to the top and bottom pvc pipes, holding the runs in place, and connecting them to the system
  • Modular, as as many as wanted can be added to a cut section of HT PVC Pipe

Control Box

  • Arduino and/or Rpi
  • Takes Sensor Data, and IO Settings in
  • Controls the Pump

Temperature Probe

  • 1 at each end of the collector panel (two total)
  • 1 in the working fluid tank
  • 1 at each end of the tank (ie to and from panel)

Pump

  • Small electric pump (calculate head needed)

Working Fluid

  • Most likely some sort of oil (higher viscosity, but will not freeze?
  • Also stores heat better

Internal Links