=Procedure=
*Select convenient length
*Select max temp - such as 550C = 1000F
*'''Match gauge to proper voltage drop of 120V''' - ie, observe parameters that produce 120V drop - those will be the working parameters since 120V is fixed.
*Find out max gauge that is within current limits (15A) and has correct voltage
*Limit for 15A outlet is 1800W
Sample:
[[File:samplenichrome.png]]
*Remains within 15 amps
*Shows correct voltage
*Max temp - select it to match voltage - you determine max possible temp and judge whether it will burn out your system if you have temperature sensitive components
*Note that Gauge 17 is the max fatness that stays within 1800W
*Note: 22' of 18 ga gets us right at 120V, and 1560W. Good. But temperature of 1260F is a little high.
[[File:nichrome2.png]]
=1000F Limit - 240V Case=
[[File:1000c.png|300px]]


=Examples=
=Examples=
*10m of 22 ga wire will draw 370W at 120V - to attain a temperature of 500F. This may be a good 12" heat bed.
==8" bed==
*15' of 24 ga wire will draw
*12' of 26 ga draws 450 Watts, but goes higher than rated 1000F
*This was acceptable, but burns out thermistors if placed directly on heater.
*Point: the shorter the nichrome, the hotter it will get while remaining at the correct voltage
*'''Keep conservative on the bed power,then. Use 14' of 26 ga for 380W and 1000F max at 120V.'''
*For same power density on large bed (7W/sq in), would need 4000W of heat. Can't do that. Limit is 1800W. the question is how best to achieve it - what length of nichrome is required for a workable length, while keeping temperature lower rather than higher.
 
==2x2 foot bed==
*1800W limit
*To cover bed - try 6 lines separated by 4" of space. This means 12' + 2 feet return or 14' of sleeve
*Gauge 17, 28' long, gets max 1090 and 1570 watts
*sleeve it in 14' of sleeve. Quite doable. needs total of 28 feet of sleeve.
*Selection:
 
[[File:finalselection.png]]
 
Shorten it by 2-4 feet to get max power and temperature.
 
=Grades of Nichrome Wire=
*60, 80, etc - https://temcoindustrial.com/product-guides/wire-cable-and-accessories/resistance-and-non-resistance-wire/nichrome-wire
*Nichrome A or C - [https://super-metals.com/news/nichrome-a-and-nichrome-c-industrial-heating-wires/]


=Links=
=Links=
*[[Insulated Heatbed]]
*[[120V Heatbed]]
*[[120V Heatbed]]

Latest revision as of 07:09, 18 February 2021

Procedure

  • Select convenient length
  • Select max temp - such as 550C = 1000F
  • Match gauge to proper voltage drop of 120V - ie, observe parameters that produce 120V drop - those will be the working parameters since 120V is fixed.
  • Find out max gauge that is within current limits (15A) and has correct voltage
  • Limit for 15A outlet is 1800W

Sample:

Samplenichrome.png

  • Remains within 15 amps
  • Shows correct voltage
  • Max temp - select it to match voltage - you determine max possible temp and judge whether it will burn out your system if you have temperature sensitive components
  • Note that Gauge 17 is the max fatness that stays within 1800W
  • Note: 22' of 18 ga gets us right at 120V, and 1560W. Good. But temperature of 1260F is a little high.

Nichrome2.png

1000F Limit - 240V Case

Error creating thumbnail: File missing

Examples

8" bed

  • 12' of 26 ga draws 450 Watts, but goes higher than rated 1000F
  • This was acceptable, but burns out thermistors if placed directly on heater.
  • Point: the shorter the nichrome, the hotter it will get while remaining at the correct voltage
  • Keep conservative on the bed power,then. Use 14' of 26 ga for 380W and 1000F max at 120V.
  • For same power density on large bed (7W/sq in), would need 4000W of heat. Can't do that. Limit is 1800W. the question is how best to achieve it - what length of nichrome is required for a workable length, while keeping temperature lower rather than higher.

2x2 foot bed

  • 1800W limit
  • To cover bed - try 6 lines separated by 4" of space. This means 12' + 2 feet return or 14' of sleeve
  • Gauge 17, 28' long, gets max 1090 and 1570 watts
  • sleeve it in 14' of sleeve. Quite doable. needs total of 28 feet of sleeve.
  • Selection:

Finalselection.png

Shorten it by 2-4 feet to get max power and temperature.

Grades of Nichrome Wire

Links