Seed Eco-Home 3 3D CAD: Difference between revisions
No edit summary |
(Added a Category to the Page) |
||
(One intermediate revision by one other user not shown) | |||
Line 21: | Line 21: | ||
{{Hint|These modules now have a single center stud instead of two studs at 16" centers}} | {{Hint|These modules now have a single center stud instead of two studs at 16" centers}} | ||
===Modules=== | ===Modules in FreeCab=== | ||
These wall panels use 10' OSB on the exterior. The OSB is offset 0.75" to the left and 1" down on each panel to help align the panel sides, sill, and top plate during installation. The interior side has small temporary | These wall panels use 10' OSB on the exterior. The OSB is offset 0.75" to the left and 1" down on each panel to help align the panel sides, sill, and top plate during installation. The interior side has small temporary tabs of 4" x 4" OSB added to assist with alignment. | ||
<gallery perrow=6> | <gallery perrow=6> | ||
Line 67: | Line 67: | ||
</gallery> | </gallery> | ||
[[Category: Seed Eco-Home]] |
Latest revision as of 00:57, 6 January 2022
Updated Walls
Updated wall modules https://drive.google.com/drive/folders/1g7LEFEEsaIRU5bAUBurge6YieXr0s1pV?usp=sharing
1st story all assembly (some details on the modules are outdated, do not use these as reference to build modules, only for assembly purposes) https://drive.google.com/drive/folders/1Lp3ILl0fBzTP_3jjFQgMABeLTGtGfYU9?usp=sharing
Vertical assembly simulation File: https://drive.google.com/file/d/1mX8w3RzRHFxx48XEXSSdMaGa9ojHOana/view?usp=sharing
Folder (it's the wall modules assembly file): https://drive.google.com/drive/folders/1sRERDUL_lp9ukx1uFnxZNu26VTATVoJo?usp=sharing
Concept / Changes from v2
v3 update
Modules in FreeCab
These wall panels use 10' OSB on the exterior. The OSB is offset 0.75" to the left and 1" down on each panel to help align the panel sides, sill, and top plate during installation. The interior side has small temporary tabs of 4" x 4" OSB added to assist with alignment.
- Error creating thumbnail: File missing
Full Panel
FreeCAD Detail-
File:Seh3 full panel.FCStd
FreeCAD Simple-
File:Seh3 full panel-simple.FCStd - Error creating thumbnail: File missing
Long Left Corner
FreeCAD Detail-
File:Seh3 long left corner.FCStd
FreeCAD Simple-
File:Seh3 long left corner-simple.FCStd - Error creating thumbnail: File missing
Long Right Corner
FreeCAD Detail-
File:Seh3 long right corner.FCStd
FreeCAD Simple-
File:Seh3 long right corner-simple.FCStd - Error creating thumbnail: File missing
Short Left Corner
FreeCAD Detail-
File:Seh3 short left corner.FCStd
FreeCAD Simple-
File:Seh3 short left corner-simple.FCStd - Error creating thumbnail: File missing
Short Right Corner
FreeCAD Detail-
File:Seh3 short right corner.FCStd
FreeCAD Simple-
File:Seh3 short right corner-simple.FCStd - Error creating thumbnail: File missing
Window Panel
FreeCAD Detail-
File:Seh3 small window.FCStd
FreeCAD Simple-
File:Seh3 small window-simple.FCStd - Error creating thumbnail: File missing
Example
FreeCAD Detail-
File:Seh3 example.FCStd
Roof
- Error creating thumbnail: File missing
Second Story Roof Assembly. Includes joists, OSB, Insulation Box, Insulation, EPDM - FreeCAD - File:SecondStoryRoofv3.fcstd.
- Error creating thumbnail: File missing
Roof Joists. - FreeCAD - File:Roofjoists.fcstd.
- Error creating thumbnail: File missing
Roof Joist Blocking. - FreeCAD - File:Roofjoistblocking.fcstd.
- Error creating thumbnail: File missing
Roof Insulation Box v2. - FreeCAD - File:RoofInsulationBox2.FCStd.
- Error creating thumbnail: File missing
Rigid Insulation. - FreeCAD - File:Rigidinsulation.fcstd.
- Error creating thumbnail: File missing
EPDM. - FreeCAD - File:Epdm.fcstd.
- Error creating thumbnail: File missing
Roof angle for roof is 1.2 Degrees. - FreeCAD - File:Roofangle.fcstd.
- Error creating thumbnail: File missing
Roof Riser Assembly - FreeCAD - File:RoofRiserAssembly.fcstd.
- Error creating thumbnail: File missing
"Roof OSB"- FreeCAD - File:Roof OSB.FCStd.