Plumbing Venting: Difference between revisions

From Open Source Ecology
Jump to navigation Jump to search
Line 34: Line 34:
*Line color is not required to match water temperature. [https://www.thespruce.com/learn-the-basics-of-pex-pipe-1822493#:~:text=Why%20PEX%20Pipes%20Are%20Ideal%20for%20Do%2DIt%2DYourselfers&text=Color%2DCoded%3A%20Red%20PEX%20pipes,the%20type%20of%20water%20supply.]
*Line color is not required to match water temperature. [https://www.thespruce.com/learn-the-basics-of-pex-pipe-1822493#:~:text=Why%20PEX%20Pipes%20Are%20Ideal%20for%20Do%2DIt%2DYourselfers&text=Color%2DCoded%3A%20Red%20PEX%20pipes,the%20type%20of%20water%20supply.]
*Water hammer arrestor is not necessary for PEX - [https://www.pmmag.com/articles/86282-water-hammer-update#:~:text=The%20plastic%20pipe%20manufacturers%20like,have%20to%20read%20any%20further.]
*Water hammer arrestor is not necessary for PEX - [https://www.pmmag.com/articles/86282-water-hammer-update#:~:text=The%20plastic%20pipe%20manufacturers%20like,have%20to%20read%20any%20further.]
*[[Air Admittance Valves]] can vent multiple fixtures on the same floor [https://www.jlconline.com/products-tools/kitchen/kitchen-bath-venting-with-air-admittance-valves_o]. Note that washer trap must empty into a 3" horizontal?


=Internal Links=
=Internal Links=

Revision as of 05:47, 13 March 2022

Concept

Vents next to traps are allowed only a limited length. You must reach a dry stack to be 'home free'. The dry stack can be any length - it is effectively as if the appliance is connected to the outside. The purpose of traps is to trap odor, the purpose of vents is to prevent water from being siphoned out of the trap.

Working Doc

edit

Design

  • Stack Vent shall be same size as soil pipe of which it's an extension - [1]
  • 2" trap must be 8' from vent, 1.5" must be 6' from vent. p. 18 of [2]. Washer needs 2" by UPC.
  • Circuit venting classifies 4" drain pipe as a horizontal vent, under the assumption that circuit is never more than at half-full capacity of 4" pipe. See p. 14 at [3]. Circuit venting means multiple fixtures with a common vent.
  • AAV inlet must be at least 4" above the horizontal it serves. [4]. But, still need one vent to outside even if you have AAVs.
  • Vent to drain distances included. Island venting. Air admittance valves. Engineered vent with sump pump and air admittance - like under sink macerator pump. [5]
  • Drainage fixture unit - DFU - 7.5gpm or cubic foot of water through 1.25" pipe. Table for appliances and DFUs - [6]. DFUs based on pipe size - 2" is 6 DFUs - [7]
  • Vents are 10' away from windows or air intakes, or 3 feet above. [8] Must be >10' above ground. [9]
  • Good openslides on basics - [10]
  • Vent stack vs stack vent - a stack vent is required in addition to vent stack for 5 stories or more [11]
  • Island venting - for example an island sink as in this video - [12] - you can use an air admittance valve, or you can use an island fixture vent loop.
  • Vent exends 6" above roof, except if roof is used for purposes other than weather protection - in which case it's 7'. [13]
  • Vent is half diameter of drain served. [14]
  • Washing machine needs a trap - [15]
  • Vent stacks can run up the side of a house - [16]
  • Total vent cross sectional area must equal total drain cross sectional area. See point 6 at [17]. Note that air admittance valves add to the total cross sectional vent area.
  • 1/8" slope per foot is acceptable for 3" pipe - [18]
  • "Once the highest branch interval is connected to the stack, the vent portion may contain offsets, provided such offsets are at least 6 inches above the branch interval connection. p. 11 in [19]
  • We use wet venting to save on the number of pipes required in the overall plumbing system. p. 12 of [20]
  • Minimum vent size is 1.25", but some cities require 1.5" such as NYC - [21]
  • Code says vent stack size must be 1/2 size of waste pipe.
  • Difference between wet vent and combination waste and vent system - [22]
  • Individual Vent must be 1/2 diameter of drain it serves, but no less than 1.25" [23]
  • Wet venting rules [24]. The bottom line is that the toilet must be the bottom line.
  • Line color is not required to match water temperature. [25]
  • Water hammer arrestor is not necessary for PEX - [26]
  • Air Admittance Valves can vent multiple fixtures on the same floor [27]. Note that washer trap must empty into a 3" horizontal?