*Go to Midnite for higher V combiners? [https://diysolarforum.com/threads/combiner-box-questions.26831/]
*Go to Midnite for higher V combiners? [https://diysolarforum.com/threads/combiner-box-questions.26831/]
*Most fuse holders are rated for 600-1000V, while DC breakers are 150V [https://solarpowercombinerbox.com/pages/what-is-a-solar-combiner-box]
*Most fuse holders are rated for 600-1000V, while DC breakers are 150V [https://solarpowercombinerbox.com/pages/what-is-a-solar-combiner-box]
*{{check}}With 600VDC YRSP-D2 [https://www.aliexpress.com/i/3256802939811681.html?gatewayAdapt=4itemAdapt] circuit breaker - [https://www.amazon.com/DEEKOOL-Upgraded-Combiner-Circuit-Waterproof/dp/B0BWHRHCD7/ref=psdc_13638744011_t3_B0BZV8ZMY2#customerReviews]
*{{check}}With 600VDC YRSP-D2 [https://www.aliexpress.com/i/3256802939811681.html?gatewayAdapt=4itemAdapt] circuit breaker - [https://www.amazon.com/DEEKOOL-Upgraded-Combiner-Circuit-Waterproof/dp/B0BWHRHCD7/ref=psdc_13638744011_t3_B0BZV8ZMY2#customerReviews]. Combined wire is fatter, at least 10 ga. Circuit breaker appears to be 600Vdc  rated [https://www.google.com/search?sxsrf=ALeKk026QG9BbsZl0rNsBS9KmerMgczY_w%3A1602863734253&source=hp&ei=dsKJX6q8DJDYsAXHkpG4Cw&q=YRL7-63DC+breaker&btnK=Google+Search&oq=how+to+configure+nvidia+geforce+gtx+1650+super+on+linux+mint&gs_lcp=CgZwc3ktYWIQAzIFCCEQoAEyBQghEKsCMgUIIRCrAjoOCAAQ6gIQtAIQmgEQ5QI6DgguELEDEMcBEKMCEJMCOggILhDHARCvAToLCC4QsQMQxwEQowI6CAgAELEDEIMBOggILhCxAxCDAToFCAAQsQM6AggAOgQIABAKOgYIABAWEB46CAghEBYQHRAeOgcIIRAKEKABUMsQWOmzAWD8tAFoBnAAeACAAeQGiAGhS5IBDTExLjQ3LjMuMi42LTGYAQCgAQGqAQdnd3Mtd2l6sAEG&sclient=psy-ab&ved=0ahUKEwiqz4DcvLnsAhUQLKwKHUdJBLcQ4dUDCAk&uact=5#imgrc=AHYzGeVEsQJmKM&btnK=Google%20Search&ip=1].
*{{check}}500VDC - [https://www.amazon.com/dp/B09ZXV3GNF?pd_rd_i=B09ZXV3GNF&pf_rd_p=781503ef-fc4a-4a05-82e1-c6ce0583b45e&pf_rd_r=P9WZ9NFCEBC5CZZZ6YPR&pd_rd_wg=6kEcd&pd_rd_w=hAkvS&pd_rd_r=c71dd655-e788-4ba1-99bf-2cb49bd1624c&th=1]. Combined output appears to have 12 ga wire, or 20A max. Would need 10 ga for 30A combined output, so this is really only good for 20A.
*{{check}}500VDC - [https://www.amazon.com/dp/B09ZXV3GNF?pd_rd_i=B09ZXV3GNF&pf_rd_p=781503ef-fc4a-4a05-82e1-c6ce0583b45e&pf_rd_r=P9WZ9NFCEBC5CZZZ6YPR&pd_rd_wg=6kEcd&pd_rd_w=hAkvS&pd_rd_r=c71dd655-e788-4ba1-99bf-2cb49bd1624c&th=1]. Combined output appears to have 12 ga wire, or 20A max. Would need 10 ga for 30A combined output, so this is really only good for 20A.



Revision as of 21:02, 29 June 2023

Amazon

  • Non-UL [1]
    • 250 VDC max input

UL Listed

  • Combiner box only $250. [2]
    • Only 125 VDC in.

Voltages

  • 1000V for this one - [3]
  • Why are others limited to 250V? Because the circuit breaker is 250V - [4]
  • Go to Midnite for higher V combiners? [5]
  • Most fuse holders are rated for 600-1000V, while DC breakers are 150V [6]
  • Check.pngWith 600VDC YRSP-D2 [7] circuit breaker - [8]. Combined wire is fatter, at least 10 ga. Circuit breaker appears to be 600Vdc rated [9].
  • Check.png500VDC - [10]. Combined output appears to have 12 ga wire, or 20A max. Would need 10 ga for 30A combined output, so this is really only good for 20A.

DIY

  • Article from 2000 in Homepower Magazine - [11]