Thermal numeracy refers to understanding the quantities of heat produced, emitted, and transferred in various physical phenomena.
Thermal numeracy refers to understanding the quantities of heat produced, emitted, and transferred in various physical phenomena.


*BTU - 1 lb water raise by 1 degree F
*BTU of wood is 8k-9k per lb -[http://extension.oregonstate.edu/lincoln/sites/default/files/home_heating_fuels_ec1628-e.pdf]
*U value of insulation is BTU/(hr*sq ft*deg F). It is the inverse of R value - [http://bwgreenhouse.ca/R-valueU-value.html]
*Fireplace heat loss from chimney can be 80-90% - [https://indianamichiganpower.com/save/eNewsletter/ViewStory.aspx?StoryID=178]
*Fireplace heat loss from chimney can be 80-90% - [https://indianamichiganpower.com/save/eNewsletter/ViewStory.aspx?StoryID=178]
*At high temperatures, temperature in degrees F is about 2x that of degrees C. Specifically, ~9/5 times.
*At high temperatures, temperature in degrees F is about 2x that of degrees C. Specifically, ~9/5 times.
*Glenwood 5000 stove is rated for 100k BTU, with 11 sf of heat exchange area - about 10k BTU/SF
*Glenwood 5000 stove is rated for 100k BTU, with 11 sf of heat exchange area - about 10k BTU/SF
*1 kW ~ 3000 BTU/hr
*1 kW ~ 3000 BTU/hr
*Black pipe is only $12/square foot (10k BTU) of heat exchange area using 1" pipe! -[https://docs.google.com/presentation/d/1xTUzDwmhszU4VwrCzDTLW_LENnYHIbPXisFgCwlOvg4/edit#slide=id.g6773fc365_0_0]
*Black pipe is only $12/square foot (10k BTU) of heat exchange area using 1" pipe! - [https://docs.google.com/presentation/d/1xTUzDwmhszU4VwrCzDTLW_LENnYHIbPXisFgCwlOvg4/edit#slide=id.g6773fc365_0_0]
*1/2" PEX power production - 22 BTU/hr for 1 foot of length - [http://www.pexuniverse.com/content/pex-tubing-sizes-floor-output]. 500 feet per trough = 11k BTU
*Cord of wood is $235, and 4000 lb - [https://www.google.com/webhp?sourceid=chrome-instant&ion=1&espv=2&ie=UTF-8&client=ubuntu#q=how%20much%20does%20a%20cord%20of%20wood%20cost]
*Thermal expansion coefficient of water is 1/10000 for F - [http://www.engineeringtoolbox.com/cubical-expansion-coefficients-d_1262.html]

Latest revision as of 01:31, 1 December 2015

Thermal numeracy refers to understanding the quantities of heat produced, emitted, and transferred in various physical phenomena.

  • BTU - 1 lb water raise by 1 degree F
  • BTU of wood is 8k-9k per lb -[1]
  • U value of insulation is BTU/(hr*sq ft*deg F). It is the inverse of R value - [2]
  • Fireplace heat loss from chimney can be 80-90% - [3]
  • At high temperatures, temperature in degrees F is about 2x that of degrees C. Specifically, ~9/5 times.
  • Glenwood 5000 stove is rated for 100k BTU, with 11 sf of heat exchange area - about 10k BTU/SF
  • 1 kW ~ 3000 BTU/hr
  • Black pipe is only $12/square foot (10k BTU) of heat exchange area using 1" pipe! - [4]
  • 1/2" PEX power production - 22 BTU/hr for 1 foot of length - [5]. 500 feet per trough = 11k BTU
  • Cord of wood is $235, and 4000 lb - [6]
  • Thermal expansion coefficient of water is 1/10000 for F - [7]