Line 1: Line 1:
family: framed_wall_panel
#redirect [[framed_wall_panel_schema.yaml]]
version: 1.0
 
description: >
  Parametric framed wall panel with selectable framed height, module width,
  stud lumber size, stud spacing, and exterior sheathing orientation.
 
dimension_convention:
  nominal_width_ft_means: framed_module_width
  nominal_height_ft_means: framed_panel_height
  description: >
    Module height refers to the framed panel height (bottom plate to top plate).
    Exterior OSB sheathing may extend above the framing and is not included in
    the nominal module height.
 
parameters:
  nominal_width_ft:
    type: float
    unit: ft
    min: 0.2708
    max: 8.0
    default: 4.0
    description: >
      Framed module width. The minimum value (0.2708 ft = 3.25 in) represents the
      smallest meaningful filler wall module that can be defined. This corresponds
      approximately to the width of two studs fastened together and represents an
      extreme lower bound used only for filler conditions between modules. Typical
      wall modules are significantly wider.
 
  nominal_height_ft:
    type: float
    unit: ft
    min: 4.0
    max: 20.0
    default: 9.0
    description: >
      Framed panel height measured from bottom plate to top plate.
 
  stud_lumber_nominal:
    type: enum
    allowed:
      - "2x2"
      - "2x3"
      - "2x4"
      - "2x6"
      - "2x8"
      - "2x10"
      - "2x12"
    default: "2x6"
    description: >
      Nominal stud and plate lumber size.
 
  stud_spacing_oc_in:
    type: enum
    allowed:
      - 16
      - 24
    default: 24
    description: >
      Stud spacing on center in inches.
 
  osb_thickness_in:
    type: enum
    allowed:
      - 0.4375
      - 0.5
      - 0.625
      - 0.75
    default: 0.4375
    description: >
      Exterior OSB sheathing thickness.
 
  exterior_face:
    type: enum
    allowed:
      - north
      - south
      - east
      - west
    default: south
    description: >
      Direction faced by the sheathed exterior side.
 
  reference_house_orientation:
    type: enum
    allowed:
      - faces_south
    default: faces_south
    description: >
      Global orientation convention.
 
design_rules:
  sheathing_layers:
    type: fixed
    value: 1
    description: >
      One layer of sheathing is used.
 
  sheathing_material:
    type: fixed
    value: OSB
    description: >
      Exterior sheathing material for this schema version.
 
  sheathing_side_rule:
    type: fixed
    value: exterior_only
    description: >
      OSB is applied only to the exterior face.
 
  standard_module_width_ft:
    type: fixed
    value: 4.0
    description: >
      Preferred standard module width.
 
  preferred_module_heights_ft:
    type: list
    values:
      - 8.0
      - 9.0
      - 10.0
    description: >
      Preferred standard framed panel heights.
 
interfaces:
  left_edge:
    type: wall_edge
    orientation: west
    description: >
      Left connection edge in local module coordinates.
 
  right_edge:
    type: wall_edge
    orientation: east
    description: >
      Right connection edge in local module coordinates.
 
  top_edge:
    type: wall_edge
    orientation: up
    description: >
      Top edge of module.
 
  bottom_edge:
    type: wall_edge
    orientation: down
    description: >
      Bottom edge of module.
 
derived_fields:
  stud_actual_thickness_in:
    source: stud_lumber_nominal
    description: >
      Actual lumber thickness derived from nominal stud size.
 
  stud_actual_depth_in:
    source: stud_lumber_nominal
    description: >
      Actual lumber depth derived from nominal stud size.
 
  framed_panel_thickness_in:
    formula: stud_actual_depth_in
    description: >
      Framed wall thickness before exterior sheathing.
 
  overall_panel_thickness_in:
    formula: stud_actual_depth_in + osb_thickness_in
    description: >
      Total panel thickness including exterior OSB.
 
  panel_family_id:
    formula: >
      wall_{nominal_width_ft}x{nominal_height_ft}_{stud_lumber_nominal}_{stud_spacing_oc_in}oc_osb{osb_thickness_in}_{exterior_face}
    description: >
      Deterministic identifier for compiled module variants.
 
constraints:
  - nominal_width_ft >= 0.2708
  - nominal_width_ft <= 8.0
  - nominal_height_ft >= 4.0
  - nominal_height_ft <= 20.0
  - stud_spacing_oc_in in [16,24]
  - stud_lumber_nominal in ["2x2","2x3","2x4","2x6","2x8","2x10","2x12"]
  - osb_thickness_in in [0.4375,0.5,0.625,0.75]
  - exterior_face in [north,south,east,west]

Latest revision as of 01:47, 11 March 2026