Line 10: | Line 10: | ||
*Black pipe is only $12/square foot (10k BTU) of heat exchange area using 1" pipe! - [https://docs.google.com/presentation/d/1xTUzDwmhszU4VwrCzDTLW_LENnYHIbPXisFgCwlOvg4/edit#slide=id.g6773fc365_0_0] | *Black pipe is only $12/square foot (10k BTU) of heat exchange area using 1" pipe! - [https://docs.google.com/presentation/d/1xTUzDwmhszU4VwrCzDTLW_LENnYHIbPXisFgCwlOvg4/edit#slide=id.g6773fc365_0_0] | ||
*1/2" PEX power production - 22 BTU/hr for 1 foot of length - [http://www.pexuniverse.com/content/pex-tubing-sizes-floor-output]. 500 feet per trough = 11k BTU | *1/2" PEX power production - 22 BTU/hr for 1 foot of length - [http://www.pexuniverse.com/content/pex-tubing-sizes-floor-output]. 500 feet per trough = 11k BTU | ||
*Cord of wood is $235, and 4000 lb. |
Revision as of 22:48, 8 October 2015
Thermal numeracy refers to understanding the quantities of heat produced, emitted, and transferred in various physical phenomena.
- BTU - 1 lb water raise by 1 degree F
- BTU of wood is 8k-9k per lb -[1]
- U value of insulation is BTU/(hr*sq ft*deg F). It is the inverse of R value - [2]
- Fireplace heat loss from chimney can be 80-90% - [3]
- At high temperatures, temperature in degrees F is about 2x that of degrees C. Specifically, ~9/5 times.
- Glenwood 5000 stove is rated for 100k BTU, with 11 sf of heat exchange area - about 10k BTU/SF
- 1 kW ~ 3000 BTU/hr
- Black pipe is only $12/square foot (10k BTU) of heat exchange area using 1" pipe! - [4]
- 1/2" PEX power production - 22 BTU/hr for 1 foot of length - [5]. 500 feet per trough = 11k BTU
- Cord of wood is $235, and 4000 lb.