Biodigester effluent may also be treated in a secondary treatment phase such as Ultrafiltration, Ultraviolet Light (UV), a Treatment Wetland, Composting, or Aerobic Treatment. Ultra filtration consists of running the effluent through a membrane that only allows solubles to pass through. At the moment this technology is more likely to be used in the developed world but appropriate solutions using materials such as mangroves and other plants might be used. Ultrafiltration is practical for concentrated wastewaters that have had most solids settled out. UV treatment is a common water treatment technology however may only be practical for dilute effluents where turbidity is not an issue. A treatment wetland provides additional treatment as well as habitat for wildlife. Essentially a movement gradient is created and planted with wetland plants that facilitate nutrient and pathogen removal. This is the way wastewaters, such as storm runoff, are naturally treated in the environment. A composting process maybe allowed used to treat the effluent however it must first be dried to facilitate aeration, which is land and energy intensive. Care must be made to ensure that no one breathes in the dust from the fresh effluent during this process. The effluent may also go through an aerobic treatment process to polish the effluent however this is expensive, intensive, and removes nutrients from a productive system. Other waste treatment options may include sand filters and clarifiers. | "Biodigester effluent may also be treated in a secondary treatment phase such as Ultrafiltration, Ultraviolet Light (UV), a Treatment Wetland, Composting, or Aerobic Treatment [http://www.sulabhinternational.org/effluent-treatment-system/]. Ultra filtration consists of running the effluent through a membrane that only allows solubles to pass through. At the moment this technology is more likely to be used in the developed world but appropriate solutions using materials such as mangroves and other plants might be used. Ultrafiltration is practical for concentrated wastewaters that have had most solids settled out. UV treatment is a common water treatment technology however may only be practical for dilute effluents where turbidity is not an issue. A treatment wetland provides additional treatment as well as habitat for wildlife. Essentially a movement gradient is created and planted with wetland plants that facilitate nutrient and pathogen removal. This is the way wastewaters, such as storm runoff, are naturally treated in the environment. A composting process maybe allowed used to treat the effluent however it must first be dried to facilitate aeration, which is land and energy intensive. Care must be made to ensure that no one breathes in the dust from the fresh effluent during this process. The effluent may also go through an aerobic treatment process to polish the effluent however this is expensive, intensive, and removes nutrients from a productive system. Other waste treatment options may include sand filters and clarifiers." [http://www.appropedia.org/Biogas_from_human_waste Biogas from human waste] | ||
[http://www.appropedia.org/Biogas_from_human_waste Biogas from human waste] | |||
Line 71: | Line 69: | ||
*Biogas from human waste - [http://www.appropedia.org/Biogas_from_human_waste] | *Biogas from human waste - [http://www.appropedia.org/Biogas_from_human_waste] | ||
*Effluent Treatment System - [http://www.sulabhinternational.org/effluent-treatment-system/] |
Revision as of 03:25, 21 October 2016
See Solar Cities Version
Janice Kelsey runs (not CSA but) ASC effort - Agriculture Supported Community - https://www.linkedin.com/in/janicekelsey
Concept + Technique
Pathogen Risk
"Wastes of animal and human origin, used as AD feedstock, contain various pathogenic bacteria, parasites and viruses. Pathogenic species that are regularly present in animal manures, slurries and household waste are bacteria (e.g. Salmonellae, Enterobacter, Clostridiae, Listeria), parasites (e.g. Ascaris, Trichostrangylidae, Coccidae), viruses and fungi. Co-digestion of abattoir and fish-processing wastes, sewage sludge and biowaste increases the diversity of pathogens that are likely to be land-spread and could enter the animal and human food chains" Biogas Handbook p.105-106
Pathogen Risk Mitigation
"Effective pathogen reduction in digestate is provided by implementation of a separate presanitation process, for the feedstock types which require special sanitation (e.g. waste waters from slaughter houses, food and catering wastes, flotation sludge). For feedstock types which do not require separate sanitation (animal manure and slurries, energy crops, vegetable residues of all kinds) the necessary sanitation and pathogen reduction is ensured by the AD process itself. Some process parameters, such as temperature, retention time inside the digester, pH etc., have direct or indirect influence on the sanitation efficiency of the AD process.
Temperature The process temperature has a sanitation effect on the supplied substrates. In case of pretreatment of feedstock, the efficiency of pathogen reduction increases with the increasing temperatures.
Retention time In the case of biogas plants treating animal manure and slurries, vegetable biomass from farming activities as well as other non-problematic feedstock types, sanitation is a result of combined temperatures and MGRT. The influence of temperature and MGRT on destruction of pathogens is highlighted in Table 9.4, showing decimation times for some common pathogen types from animal slurries. In case of e.g. Salmonella typhi murium, the destruction of 90% of the population occurs in 0,7 hours in a digester running at 53oC (thermophilic digestion), in 2,4 days in a digester operating at 35oC (mesophilic digestion), but the same reduction of Salmonella can take 2 to 6 weeks at ambient temperature, in untreated slurry.
Digester system In fully mixed digesters, the fresh feedstock can always contaminate the already sanitised substrate. Even in a plug flow reactor, where the particles move evenly through the reactor, short cuts cannot be prevented. Therefore, a minimum retention time in mixed reactors cannot be fully guaranteed. This can only be ensured in a batch (discontinuous) system, where the digester is firstly filled up and then completely emptied after digesting (e.g. batch method of dry AD system)."
Post treatment and sterilization
"Biodigester effluent may also be treated in a secondary treatment phase such as Ultrafiltration, Ultraviolet Light (UV), a Treatment Wetland, Composting, or Aerobic Treatment [1]. Ultra filtration consists of running the effluent through a membrane that only allows solubles to pass through. At the moment this technology is more likely to be used in the developed world but appropriate solutions using materials such as mangroves and other plants might be used. Ultrafiltration is practical for concentrated wastewaters that have had most solids settled out. UV treatment is a common water treatment technology however may only be practical for dilute effluents where turbidity is not an issue. A treatment wetland provides additional treatment as well as habitat for wildlife. Essentially a movement gradient is created and planted with wetland plants that facilitate nutrient and pathogen removal. This is the way wastewaters, such as storm runoff, are naturally treated in the environment. A composting process maybe allowed used to treat the effluent however it must first be dried to facilitate aeration, which is land and energy intensive. Care must be made to ensure that no one breathes in the dust from the fresh effluent during this process. The effluent may also go through an aerobic treatment process to polish the effluent however this is expensive, intensive, and removes nutrients from a productive system. Other waste treatment options may include sand filters and clarifiers." Biogas from human waste