Tools Required

solder iron heat gun wire cutter/stripper lighter

Materials Required

hall effects sensor 1/2" poly pipe 5/8" o.d. underground telephone cable 4 wire potting compound disposable mixing cups tape cat5 cable shrink wrap

Diagrams

Fabrication Steps

  1. cut telephone cable 70" long
  2. strip shielding plastic 1.5" and 8" at either end
  3. solder hall effects sensor