CEB Press/Manufacturing Instructions/Sensor Unit: Difference between revisions

From Open Source Ecology
Jump to navigation Jump to search
No edit summary
Line 32: Line 32:
# strip shielding plastic 1.5" and 8" at either end
# strip shielding plastic 1.5" and 8" at either end
# solder hall effects sensor
# solder hall effects sensor
[[Image:Cebpress-sensorunit-pourcompound.jpg|thumb]]

Revision as of 05:40, 5 September 2011

Main > Housing and construction > CEB Press > CEB press building instructions

Main-cyl-sensor.jpg


Tools Required

  • solder iron
  • heat gun
  • wire cutter/stripper
  • lighter

Materials Required

  • hall effects sensor
  • 1/2" poly pipe 5/8" o.d.
  • underground telephone cable 4 wire
  • potting compound
  • disposable mixing cups
  • tape
  • cat5 cable
  • shrink wrap

Diagrams

Fabrication Steps

  1. cut telephone cable 70" long
  2. strip shielding plastic 1.5" and 8" at either end
  3. solder hall effects sensor
Cebpress-sensorunit-pourcompound.jpg