Line 7: | Line 7: | ||
=Motors= | =Motors= | ||
*TSINY TRS-775W - spec sheet [http://www.tsinymotor.com/Products/DC_Motor/2014/0517/53.html] - 220W, 17A at 17V for max efficiency | *TSINY TRS-775W - spec sheet [http://www.tsinymotor.com/Products/DC_Motor/2014/0517/53.html] no l | ||
**- 220W, 17A at 17V for max efficiency. 2.4 no load. | |||
**12V no load 1.4A. Take 1.4/2.4 * 17A = 10A - or 120W at 12V. Just about right. | |||
**.75*120=90W. That is about right - for |