Motors
- TSINY TRS-775W - spec sheet [1]
- 220W, 17A at 17V for max efficiency. 2.4 no load.
- 12V no load 1.4A. Take 1.4/2.4 * 17A = 10A - or 120W at 12V. Just about right.
- .75*120=90W. That is about right - for