Electrical Inspection: Difference between revisions
Jump to navigation
Jump to search
Line 7: | Line 7: | ||
*Wires cable-stapled to studs | *Wires cable-stapled to studs | ||
*Wires 1.25" below surface, or need protective metal plates. [https://www.process.st/checklist/electrical-inspection-checklist-residential-rough-inspection-general/] | *Wires 1.25" below surface, or need protective metal plates. [https://www.process.st/checklist/electrical-inspection-checklist-residential-rough-inspection-general/] | ||
*Check appropriate conductor fill of boxes. [https://www.ecmweb.com/national-electrical-code/code-basics/article/20886012/box-fill-calculations] |
Revision as of 15:52, 28 May 2021
- How to pass - [1]
Guidelines
- No devices are installed, just wires and boxes
- PLug holes between floors with insulation of fire block foam to prevent fire spread [2]
- All wires have wire nuts on them at rough-in
- Wires cable-stapled to studs
- Wires 1.25" below surface, or need protective metal plates. [3]
- Check appropriate conductor fill of boxes. [4]