*Wires 1.25" below surface, or need protective metal plates. [https://www.process.st/checklist/electrical-inspection-checklist-residential-rough-inspection-general/]  | *Wires 1.25" below surface, or need protective metal plates. [https://www.process.st/checklist/electrical-inspection-checklist-residential-rough-inspection-general/]  | ||
*Check appropriate conductor fill of boxes. [https://www.ecmweb.com/national-electrical-code/code-basics/article/20886012/box-fill-calculations]  | *Check appropriate conductor fill of boxes. [https://www.ecmweb.com/national-electrical-code/code-basics/article/20886012/box-fill-calculations]  | ||
*Rough-in electrical has wires run and boxes attached, wires sticking out 8" and attached to box, with at least 1/4" of insulation after the attachment to box. Use large boxes so you always have enough room for the necessary wires.  | |||
Revision as of 16:08, 28 May 2021
- How to pass - [1]
 
Guidelines
- No devices are installed, just wires and boxes
 - PLug holes between floors with insulation of fire block foam to prevent fire spread [2]
 - All wires have wire nuts on them at rough-in
 - Wires cable-stapled to studs
 - Wires 1.25" below surface, or need protective metal plates. [3]
 - Check appropriate conductor fill of boxes. [4]
 - Rough-in electrical has wires run and boxes attached, wires sticking out 8" and attached to box, with at least 1/4" of insulation after the attachment to box. Use large boxes so you always have enough room for the necessary wires.