*Impedance of a lawn mower battery - 3 ma? [https://www.google.com/search?q=impedance+of+a+lead+acid+battery&sxsrf=APq-WBsKDWmkXApsg7PtLtNWbFPZOY7NLw%3A1647957754717&ei=-tY5YvOwK_O1qtsP3vmx8AE&ved=0ahUKEwjzlcyE8dn2AhXzmmoFHd58DB4Q4dUDCA4&uact=5&oq=impedance+of+a+lead+acid+battery&gs_lcp=Cgdnd3Mtd2l6EAM6BwgAEEcQsAM6BQghEKsCOgQIIRAKSgQIQRgASgQIRhgAUIIGWK0PYP0PaAFwAXgAgAFUiAHqBJIBATmYAQCgAQHIAQjAAQE&sclient=gws-wiz]
*Impedance of a lawn mower battery - 3 ma? [https://www.google.com/search?q=impedance+of+a+lead+acid+battery&sxsrf=APq-WBsKDWmkXApsg7PtLtNWbFPZOY7NLw%3A1647957754717&ei=-tY5YvOwK_O1qtsP3vmx8AE&ved=0ahUKEwjzlcyE8dn2AhXzmmoFHd58DB4Q4dUDCA4&uact=5&oq=impedance+of+a+lead+acid+battery&gs_lcp=Cgdnd3Mtd2l6EAM6BwgAEEcQsAM6BQghEKsCOgQIIRAKSgQIQRgASgQIRhgAUIIGWK0PYP0PaAFwAXgAgAFUiAHqBJIBATmYAQCgAQHIAQjAAQE&sclient=gws-wiz]
*Test - can 4 lawn mower batteries support a PV system of 3kW for 6 hours? Can 2 batteries do it?
*Test - can 4 lawn mower batteries support a PV system of 3kW for 6 hours? Can 2 batteries do it?
**A battery has total max of 400Whr - so it is 80Whr sustainably. 4 batteries support 1600W for 1 hour. If voltage does not drop when using say 2 kW - then the power is going directly from charge controller to inverter.
**A battery has total max of 400Whr - so it is 80Whr sustainably. 4 batteries support 1600W for 1 hour. If voltage does not drop when using say 2 kW of load continuously - then the power is going directly from charge controller to inverter.

Latest revision as of 14:14, 22 March 2022

  • Up to 400W - [1]
  • Lawn mower batteries are larger than motorcycle batteries [2]
  • Mower batteries last 4 years [3]
  • Lead acid is good for 1000 charge cycles. [4]
  • Tesla batteries are good for 1500 charge cycles [5]
  • Good U1 battery is 20A for 60 minutes [6].
  • U1 - Walmart 340 CCA - [7]
  • U1 - $25 - 230 CCA - [8]
    • Note U1-R - R refers to Right side for terminal
  • U1 bats have 35 ahr at 10 hr rate [9]
  • If we have 20% of battery capacity available for lawn mower bats, that is 7 ahr. 4 batteries have 28Ahr - at 12V that makes for 336 watts.
  • Cranking amps are 5-10 seconds. At 230 CCA - we have about 900A or 11kW.
  • Impedance of a lawn mower battery - 3 ma? [10]
  • Test - can 4 lawn mower batteries support a PV system of 3kW for 6 hours? Can 2 batteries do it?
    • A battery has total max of 400Whr - so it is 80Whr sustainably. 4 batteries support 1600W for 1 hour. If voltage does not drop when using say 2 kW of load continuously - then the power is going directly from charge controller to inverter.