Programming: [https://docs.google.com/presentation/d/1IglMwlvzJzA5S6ePZJcBh-0rtOnXw41Hl-RiOQfvbNk/edit?slide=id.g33327038b48_0_0#slide=id.g33327038b48_0_0] | Programming: [https://docs.google.com/presentation/d/1IglMwlvzJzA5S6ePZJcBh-0rtOnXw41Hl-RiOQfvbNk/edit?slide=id.g33327038b48_0_0#slide=id.g33327038b48_0_0] | ||
= Genie 7055 Garage Door Opener LED Status Codes = | = Genie 7055 Garage Door Opener LED Status Codes = | ||
Source - [https://chatgpt.com/share/69ab74fd-77e0-8010-9f81-7bc3ddb8b8dd] | |||
{| class="wikitable" | {| class="wikitable" | ||
Revision as of 00:45, 7 March 2026
Programming: [1]
Genie 7055 Garage Door Opener LED Status Codes
Source - [2]
| System State | Opener Round LED (Blue) | Opener Long LED (Purple) | Sensor LEDs (Red / Green) | Meaning | Typical Action |
|---|---|---|---|---|---|
| Normal operation (fully programmed, ready) | Solid Blue | Off | Red solid / Green solid | System powered and operating normally | None required |
| Programming mode entered | Flashing Blue | Off | Red solid / Green solid | User pressed SET/PROGRAM to begin programming | Continue programming steps |
| Ready to program remote | Flashing Blue | Flashing Purple | Red solid / Green solid | Opener waiting for remote signal | Press remote button to pair |
| Travel limit programming mode | Blue on | Purple flashing | Red solid / Green solid | System waiting for UP/DOWN limits to be set | Set open and close positions |
| Door closing normally | Blue solid | Off | Red solid / Green solid | Normal closing operation | None |
| Door opening normally | Blue solid | Off | Red solid / Green solid | Normal opening operation | None |
| Safe-T-Beam blocked | Blue solid | Off | Red solid / Green flashing | Beam interrupted or object in doorway | Remove obstruction |
| Safe-T-Beam misaligned | Blue solid | Off | Red flashing / Green off or flashing | Sensors not aligned | Realign sensors |
| Safe-T-Beam wiring fault | Blue solid | Off | Red off / Green off | Sensor wiring disconnected or damaged | Inspect wiring to sensors |
| Door will not close unless wall button held | Blue solid | Off | Red flashing or Green flashing | Safety beam not detected | Fix sensor alignment or wiring |
| Power outage / battery backup mode | Blue may blink slowly or dim | Off | Red solid / Green solid | Opener running on battery backup | Restore AC power |
| System memory reset / no limits stored | Blue flashing | Purple flashing | Red solid / Green solid | Limits not programmed | Perform travel limit setup |
| Overcurrent / obstruction detected | Blue solid | Off | Red solid / Green solid | Door encountered resistance while moving | Check door tracks, springs, obstruction |