CEB Press/Manufacturing Instructions/Valve Mount: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{Category=CEB press building instructions}} | {{Category=CEB press building instructions}} | ||
=Part Information | |||
The valve mount holds the hydraulic solenoid valves to the primary arm. | The valve mount holds the hydraulic solenoid valves to the primary arm. | ||
Line 26: | Line 28: | ||
*Punch 2 holes of 13/16" diameter that are centered 20cm from each other and 3cm from the bottom edge of the steel plate. | *Punch 2 holes of 13/16" diameter that are centered 20cm from each other and 3cm from the bottom edge of the steel plate. | ||
[[Image:ValveMount.png]] |
Revision as of 00:23, 23 December 2011
Main > Housing and construction > CEB Press > CEB press building instructions
=Part Information
The valve mount holds the hydraulic solenoid valves to the primary arm.
Tools
- Hole puncher with 13/16" Dies
- Drill Press with 5/16" or larger bit.
Materials
- Steel plate 1/4" x 6" x 12"
- Solenoid Valve Set
Steps
- Set the steel plate on a flat surface
- Position the solenoid valve set over the plate such that its work port surface is flush with the top edge and square with the side edges of the steel plate.
- Using the marking utensil and the center punch, mark then center punch the 4 aligned holes at the sides of the steel plate
- Drill 4 holes of 5/16" diameter at the marked points of the steel plate
- Punch 2 holes of 13/16" diameter that are centered 20cm from each other and 3cm from the bottom edge of the steel plate.