Mike Hill Plasma Table: Difference between revisions

From Open Source Ecology
Jump to navigation Jump to search
(Created page with "I attached three photos of my initial test with .5" plate. The test hole was .75 inches. [1561] picture from the front side just after cutting [1565] picture from the bac...")
 
No edit summary
 
Line 14: Line 14:


[[Image:mhhole1.jpg]]
[[Image:mhhole1.jpg]]
[[Image:mhhole2.jpg]]


[[Image:mhhole3.jpg]]
[[Image:mhhole3.jpg]]
[[Image:mhhole2.jpg]]

Latest revision as of 00:11, 11 March 2013

I attached three photos of my initial test with .5" plate. The test hole was .75 inches.

[1561] picture from the front side just after cutting

[1565] picture from the backside before dross removal

[1571] picture from the backside after removing the dross with a metal scraper.

The dross was very lightly attached so removal only took a few seconds.

I measured the hole from the front side with calipers and the cut was within 1/64" of an inch. The backside was within 1/32". The plasma arc creates a natural bevel so the backside will always be slightly smaller. If you needed more precision than that we could cut the holes smaller by 1/32" and then chase them through with the correct sized drill bit. With most of the material removed this should be a pretty quick operation.

If you need any parts cut let me know.

Mhhole1.jpg

Mhhole2.jpg

Mhhole3.jpg