Air Motors

From Open Source Ecology
Revision as of 16:55, 28 February 2021 by Marcin (talk | contribs)
Jump to navigation Jump to search
  • This one says 70% efficient - really? [1]
  • CFM of 20 gets 1 hp about. 1 cu m is 35 cf. 1 cu m at 190 atm is 7000 cf, at 20 cfm gives 350 minutes or almost 6 hours.
  • 7 cfm, 0.2 hp - $250 - [2].
  • 14 cfm gets me the right power - 0.4 hp or 300W.

Power Out

  • 1 cubic meter of air storage - at 200atm - gets you 7000 cfm at stp. Since we need to save 10 atm to run, have 190 atm available - so 5% negligible loss - most is usable air. This is 500 minutes of air - 8 hours - of 300W - or 2.4kW hrs! This is just plain adiabatic.
  • Thus, having access to 1 cu m of stored air - is key - for an inefficient storage system.
  • .