Revision as of 22:48, 18 November 2017 by Marcin (talk | contribs) (Created page with "*Initial pump used - .92 cu in as in BOM - for 1950 max PSI and 14 gpm *To achieve 3000 PSI, a ~9 gpm pump is needed if the engine is 16 hp. *This .61 cu in pump [http://www.s...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
  • Initial pump used - .92 cu in as in BOM - for 1950 max PSI and 14 gpm
  • To achieve 3000 PSI, a ~9 gpm pump is needed if the engine is 16 hp.
  • This .61 cu in pump [1] has 8.8 gpm flow and requires 15.5 hp to drive according to Hydraulic Calculations