Quality Control Requirements - 12 Kits at a Time
To test 12 kits at a time, it is useful to set up rapid testing procedures for parts.
From the 3D Printer Packing List:
Perfect Prints
To guarantee perfect prints, the following conditions must be met:
- Extruder steps per mm are correct. See Triffid Hunter's Calibration Guide
- Axes must be loose. See 3D Printer Manual - final assembly for procedure to mount axes
Corresponing Quality Control Steps for Perfect Prints
- E steps/mm must be done only once, and must be captured in Marlin or in Start G-Code
- Measure axis tightness using a force meter. Use a Digital Scale to record the force required to move an axis.
Links
- For OSE's 3D printer stable release, this can be done once: Triffid Hunter's Calibration Guide