Electrical Inspection
Jump to navigation
Jump to search
- How to pass - [1]
Guidelines
- No devices are installed, just wires and boxes
- PLug holes between floors with insulation of fire block foam to prevent fire spread [2]
- All wires have wire nuts on them at rough-in
- Wires cable-stapled to studs
- Wires 1.25" below surface, or need protective metal plates. [3]
- Check appropriate conductor fill of boxes. [4]
- Rough-in electrical has wires run and boxes attached, wires sticking out 8" and attached to box, with at least 1/4" of insulation after the attachment to box. Use large boxes so you always have enough room for the necessary wires.
- Cable anchors 8" from box and no more than 4' spacing thereafter [5]
- The horizontal runs should be at least 20 to 24 inches above the floor - [6]