User contributions for Marcin
Jump to navigation
Jump to search
20 February 2026
- 22:1322:13, 20 February 2026 diff hist +389 N OSE Formula Created page with "This is the standard OSE playbook: *Use open source technology, develop it, and publish early and often *Develop up to robust productization *Prove revenue models around the product by dogfooding. *Integrate products developed into a working civilization startup experiment, such as Civilization 100 or Civilization 10000. *Continue to optimize *Create Universal Basic Resources"
- 22:1122:11, 20 February 2026 diff hist +399 Organizational Log →Jan 2026
- 22:0922:09, 20 February 2026 diff hist +686 Organizational Log →Mon Jan 12, 2026
- 22:0222:02, 20 February 2026 diff hist +35 Marcin Log →Thu Feb 19, 2026
- 22:0022:00, 20 February 2026 diff hist +49 Marcin Log →Thu Feb 19, 2026
- 21:0721:07, 20 February 2026 diff hist +43 SCALE No edit summary current
- 21:0621:06, 20 February 2026 diff hist +402 N SCALE Created page with "''Just a heads up, we are the largest open source conference in North America completely community run and only 2nd to All Things Open, (which can get 5-6k audience and is not completely community run). If you are looking for community that lives and breathes open source, this is the place to be. Turning down the spot after being accepted would likely keep you off the speaker list moving forward. ''"
- 21:0621:06, 20 February 2026 diff hist +11 Conferences →Open Source current
- 21:0621:06, 20 February 2026 diff hist +24 Conferences →Open Source
- 21:0521:05, 20 February 2026 diff hist +16 Marcin Log →Thu Feb 19, 2026
- 20:3020:30, 20 February 2026 diff hist −1 Seed Eco-Home 6 Data Collection →Heat Pump Rework - Feb 5, 2026 current
- 20:2920:29, 20 February 2026 diff hist −1 Seed Eco-Home 6 Data Collection →Feb 19, 2026
- 20:2820:28, 20 February 2026 diff hist +2,459 N Seed Eco-Home 6 Data Collection Created page with "=Heat Pump Rework - Feb 5, 2026= *Initial line connections leaked. Small line had a leak (thus vacuum pull failed). Small line was re-flared. Vacuum test held vacuum, pressure test was not done assuming all is ok. Upon refrigerant release - system leaked from large fitting, while the small line was ok. Fluid potentially contaminated with air, needs refrigerant recovery and refill. =Feb 19, 2026= The basic process for recovery and refill of a leaked heat pump system wi..."
- 20:0220:02, 20 February 2026 diff hist +20 Heat Pump Sourcing →24000 BTU current
- 19:5119:51, 20 February 2026 diff hist +275 Heat Pump Sourcing →24000 BTU
- 19:5119:51, 20 February 2026 diff hist −275 Heat Pump Sourcing No edit summary
- 19:4919:49, 20 February 2026 diff hist +14 Heat Pump Sourcing →12000 BTU
- 19:4819:48, 20 February 2026 diff hist 0 Heat Pump Sourcing No edit summary
- 19:4819:48, 20 February 2026 diff hist +13 Heat Pump Sourcing No edit summary
- 19:4719:47, 20 February 2026 diff hist +9 Heat Pump Sourcing →24000 BTU
- 19:2219:22, 20 February 2026 diff hist +16 Video Gallery →All - Newest on Top
- 19:2219:22, 20 February 2026 diff hist +43 N Implements Created page with "https://photos.app.goo.gl/Sqc4XtehKsczhELY6" current
- 19:2119:21, 20 February 2026 diff hist +30 Marcin Log →Thu Feb 19, 2026
- 19:1419:14, 20 February 2026 diff hist +118 Seed Eco-Home 6 BOM →Heat Pump current
- 17:3017:30, 20 February 2026 diff hist +42 Press →Notes
- 04:5704:57, 20 February 2026 diff hist +95 Tell to Win →Notes
- 04:4504:45, 20 February 2026 diff hist +117 Tell to Win →Notes
- 04:2304:23, 20 February 2026 diff hist +68 Tell to Win →Notes
- 04:1904:19, 20 February 2026 diff hist +133 Tell to Win →Notes
- 04:1604:16, 20 February 2026 diff hist +60 Tell to Win →Notes
- 04:0904:09, 20 February 2026 diff hist +98 Hydraulic Hammer Charge No edit summary current
- 04:0504:05, 20 February 2026 diff hist +48 N Hydraulic Hammer Charge Created page with "https://youtu.be/kFaVibC6rls?si=OpK-Y2iZuzglU6U0"
- 04:0504:05, 20 February 2026 diff hist +30 Marcin Log →Thu Feb 19, 2026
- 03:5903:59, 20 February 2026 diff hist +79 N Mindsight Created page with "A ikity to look into another"s mind which comes from getting psyched up to show" current
- 03:5803:58, 20 February 2026 diff hist +15 Tell to Win →Notes
- 03:5703:57, 20 February 2026 diff hist +36 Marcin Log →Wed Feb 18, 2026
19 February 2026
- 00:0000:00, 19 February 2026 diff hist +404 N Extreme Terraforming for the Everyman Created page with "*Ponds - backhoe - high density. Field and forest, not bulldozed which requires huge area *Flowers extreme *Afforest *Afforestt Lines - myco uphill water from ponds *Extreme quantity of fruit trees, etc. Acre each of apple, pear, peach, walnut, chestnut, hazel, pawpaw, with full perennial polyculture. *Pervious pavement *Signage *Nature trail *Wood chips *Bale injection into soil *Sustainable forestry" current
18 February 2026
- 23:5823:58, 18 February 2026 diff hist +1,547 N Open Source Heat Pump Requirements + Value Proposition Created page with "Consulting for Open Heat Pump Design TO HVAC ServiceTech Hi, Love your transparent documentation. I work on open source tech - see my recent viral video - https://www.instagram.com/p/DPTpHWzjMN3/ or TED Talk in my signature. We build housing and open tech for a living. I would like to ask you if you can help us design an open source heat pump. What we would need from you is part selection for an integrated heat pump system equivalent to Senville Aura 24000 BTU or sim..." current
- 23:5723:57, 18 February 2026 diff hist +27 Marcin Log →Wed Feb 18, 2026
- 23:3823:38, 18 February 2026 diff hist +44 Marcin Log →Wed Feb 18, 2026
- 21:5921:59, 18 February 2026 diff hist +45 Contracts No edit summary current
- 21:5821:58, 18 February 2026 diff hist +158 Contracts No edit summary
- 21:5621:56, 18 February 2026 diff hist +8 Contracts No edit summary
- 21:5621:56, 18 February 2026 diff hist +67 Contracts No edit summary
- 21:5521:55, 18 February 2026 diff hist +220 Contracts →Construction Workers
- 20:5320:53, 18 February 2026 diff hist +65 Refrigerant Recovery and Recharge →About current
- 20:5320:53, 18 February 2026 diff hist +538 N Refrigerant Recovery and Recharge Created page with "=About= Here is a detailed process for recovery after a failed heat pump charge attempt. This is a specific case where after refrigerent was released from outdoor unit into the indoor unit, there was a leak, and service valves were shut. The starting point was that of most refrigerant remaining in the outdoor unit, and whatever refrigerant was released leaked into the air because there was a leak in the system. In the initial attempt, we did not do a pressure test, as th..."
- 20:5120:51, 18 February 2026 diff hist +38 Marcin Log →Wed Feb 18, 2026
- 20:4320:43, 18 February 2026 diff hist +118 FBA Apprenticeship Offer No edit summary current
- 20:4220:42, 18 February 2026 diff hist +6 FBA Apprenticeship Offer No edit summary