Fri Jan 25, 2019

  • CEB Press v16.09 - Scott II brick press - 20F temperature in workshop for testing in the snow - pressure on Surpluscenter DO3 valve was 700 psi at flowthrough on valve after CEB inlet. That is excessive. It could be the cold. It was going through 6 quick couplers - Power Cube, PC extension, CEB valve inlet, outlet, PC extension, PC. But it was on low throttle of 14 GPM. Verify that pressure is reduced significantly when it short circuits just through Power Cube.