Nichrome Wire Calculator

From Open Source Ecology
Revision as of 20:22, 25 November 2019 by Marcin (talk | contribs) (→‎Examples)
Jump to navigation Jump to search

Procedure

  • Select convenient length
  • Select max temp - such as 550C = 1000F
  • Match gauge to proper voltage drop of 120V
  • Find out max gauge that is within current limits (15A) and has correct voltage
  • Limit for 15A outlet is 1800W

Sample:

Samplenichrome.png

  • Remains within 15 amps
  • Shows correct voltage
  • Max temp - select it to match voltage - you determine max possible temp and judge whether it will burn out your system if you have temperature sensitive components
  • Note that Gauge 17 is the max fatness that stays within 1800W
  • Note: 22' of 18 ga gets us right at 120V, and 1560W. Good. But temperature of 1260F is a little high.

Nichrome2.png

Examples

  • 12' of 26 ga draws 450 Watts.
  • This was acceptable, but burns out thermistors if placed directly on heater.

Links