Plumbing Venting
Jump to navigation
Jump to search
Good reference:
Vent to drain distances included. Island venting. Air admittance valves. Engineered vent with sump pump and air admittance - like under sink macerator pump.
https://wabo.memberclicks.net/assets/pdfs/Plumbing_Venting_Brochure_2018.pdf
Design
- Vent stack vs stack vent - a stack vent is required in addition to vent stack for 5 stories or more [1]
- Vent exends 6" above roof, except if roof is used for purposes other than weather protection - in which case it's 7'. [2]
- Vent is half diameter of drain served. [3]
- Washing machine needs a trap - [4]
- Vent stacks can run up the side of a house - [5]
- Total vent cross sectional area must equal total drain cross sectional area. See point 6 at [6]. Note that air admittance valves add to the total cross sectional vent area.