Plumbing Venting
		
		
		
		Jump to navigation
		Jump to search
		
Good reference:
Vent to drain distances included. Island venting. Air admittance valves. Engineered vent with sump pump and air admittance - like under sink macerator pump.
https://wabo.memberclicks.net/assets/pdfs/Plumbing_Venting_Brochure_2018.pdf
Design
- Vent stack vs stack vent - a stack vent is required in addition to vent stack for 5 stories or more [1]
 - Island venting - for example an island sink as in this video - [2] - you can use an air admittance valve, or you can use an island fixture vent loop.
 - Vent exends 6" above roof, except if roof is used for purposes other than weather protection - in which case it's 7'. [3]
 - Vent is half diameter of drain served. [4]
 - Washing machine needs a trap - [5]
 - Vent stacks can run up the side of a house - [6]
 - Total vent cross sectional area must equal total drain cross sectional area. See point 6 at [7]. Note that air admittance valves add to the total cross sectional vent area.
 - 1/8" slope per foot is acceptable for 3" pipe - [8]