Solar Collector Losses Summary

From Open Source Ecology
Revision as of 17:33, 31 January 2009 by WikiSysop (talk | contribs)
Jump to navigation Jump to search

Introduction

When considering the overall performance of linear slat collectors for a linear Fresnel solar concentrator system oriented in the E-W direction, several losses must be considered. For the case of a 4:1 aspect ratio array, such as a 15 foot wide array that stretches for 60 feet in the E-W direction. For this case, if we use 6" slats, we can fit about 16 slats in this area, or a total of 480 square feet (45 sq meters) of solar intercept. We have about 5 kWhr/day per square meter in Maysville, Missouri - from [1]. We summarize our losses. This includes air mass losses and averages over the seasons - because we are taking empirical data. We are assumining a collector tube with a single layer of insulating glass on the surface.


  1. Reflection losses from mirrors - 1%, assuming 99% reflective mirrors - and assuming that 4% reflection from glass is reflected back at the collector tube
  2. Edge Lossses - 10% - from Solar_Collector_Calculations#Losses_due_to_edge_effects_only - about if we consider the 6 hours of highest sun during the day, or from 9:30 AM - 2:30 PM
  3. Reflection from collector tube glass - 4% loss
  4. Radiation losses from collector tube - 25% losses using selective coating as calculated in [2]