Brick Uniformity Adjustment
Procedure: press 2 bricks, document measurements on 4 corners of each side. Use form below to capture data on a smart phone or computer. After pressing 2 bricks, if result is less or equal to +/- 1/32" on each corner, you are done. Otherwise, shim the press foot accordingly.
Brick Uniformity - Data Logging