*Note- motor is 12 gpm continuous, so must be activated in parallel with other element or flow reduced
*motor is rated for 1800 psi, so pressure reducer must be used
*for 14 gpm - can use small cylinder motion to reduce flow, or just needle valve.
*for 28 gpm must have 3 solenoids going at once for shaker not to blow up
*cushion valve must be used in all cases
*to test cushion valve, observe pressure with pressure valve in manual mode
*next steps - use log splitter 2 stage pump for faster pressing