*Biogas BTUs is 600 btu per cubic foot
*Biogas BTUs is 600 btu per cubic foot - [http://journeytoforever.org/biofuel_biogas.html]
*Molecular weight of methane - 16 grams/mole
*Molecular weight of methane - 16 grams/mole
*ARTI Biogas - 1 cubic meter - and 250-500 g of gas per day. [http://www.build-a-biogas-plant.com/arti-biogas/]. 250 gal fermenter, 200 gal collector -  
*ARTI Biogas - 1 cubic meter - and 250-500 g of gas per day. [http://www.build-a-biogas-plant.com/arti-biogas/]. 250 gal fermenter, 200 gal collector -  

Revision as of 06:38, 22 May 2016

  • Biogas BTUs is 600 btu per cubic foot - [1]
  • Molecular weight of methane - 16 grams/mole
  • ARTI Biogas - 1 cubic meter - and 250-500 g of gas per day. [2]. 250 gal fermenter, 200 gal collector -
  • 1 cubic foot of methane = 5 grams
  • 1 cu meter = 35 cu ft
  • 1 cu meter methane = 175 grams methane
  • BTU to boil one gallon of water - from 60 = 1200 BTU
  • BTU is energy required to lift one pound of water 1 degree F. From 62F to 212 is 150 BTUs for one lb.
  • Efficiency of a cooktop is 30%, inductio cooktop is 80% - [3]
  • So one would need 6 cubic feet of methane to boil a gallon.