*Biogas BTUs is 600 btu per cubic foot | *Biogas BTUs is 600 btu per cubic foot - [http://journeytoforever.org/biofuel_biogas.html] | ||
*Molecular weight of methane - 16 grams/mole | *Molecular weight of methane - 16 grams/mole | ||
*ARTI Biogas - 1 cubic meter - and 250-500 g of gas per day. [http://www.build-a-biogas-plant.com/arti-biogas/]. 250 gal fermenter, 200 gal collector - | *ARTI Biogas - 1 cubic meter - and 250-500 g of gas per day. [http://www.build-a-biogas-plant.com/arti-biogas/]. 250 gal fermenter, 200 gal collector - |
Revision as of 06:38, 22 May 2016
- Biogas BTUs is 600 btu per cubic foot - [1]
- Molecular weight of methane - 16 grams/mole
- ARTI Biogas - 1 cubic meter - and 250-500 g of gas per day. [2]. 250 gal fermenter, 200 gal collector -
- 1 cubic foot of methane = 5 grams
- 1 cu meter = 35 cu ft
- 1 cu meter methane = 175 grams methane
- BTU to boil one gallon of water - from 60 = 1200 BTU
- BTU is energy required to lift one pound of water 1 degree F. From 62F to 212 is 150 BTUs for one lb.
- Efficiency of a cooktop is 30%, inductio cooktop is 80% - [3]
- So one would need 6 cubic feet of methane to boil a gallon.