Working Doc
Motors
- TSINY TRS-775W - spec sheet [1] - study spec sheet for peak vs stall power
- 220W output power, 17A at 17V for max efficiency. 2.4 no load.
- 12V no load 1.4A. Take 1.4/2.4 * 17A = 10A - or 120W at 12V. Just about right.
- .75*120=90W. That is about right - for
- RSRS-550s 18v - [2]
- 150W-180W energy use (not output power)
- Jameco - 0.6 kg cm torque at max eff - $5 -
- Jameco - 0.6 kg cm torque 78% max eff - $3 - [3]