Seed Eco-Home 3 3D CAD: Difference between revisions

From Open Source Ecology
Jump to navigation Jump to search
No edit summary
(Added a Category to the Page)
 
(15 intermediate revisions by 2 users not shown)
Line 1: Line 1:
=Roof=


<gallery>


File:roofassyv3.png|'''Second Story Roof Assembly.''' Includes joists, OSB, Insulation Box, Insulation, EPDM - FreeCAD - [[File:SecondStoryRoofv3.fcstd]].
=Updated Walls=
Updated wall modules
https://drive.google.com/drive/folders/1g7LEFEEsaIRU5bAUBurge6YieXr0s1pV?usp=sharing


File:Roofjoists.png|'''Roof Joists.''' - FreeCAD - [[File:roofjoists.fcstd]].
1st story all assembly (some details on the modules are outdated, do not use these as reference to build modules, only for assembly purposes)
https://drive.google.com/drive/folders/1Lp3ILl0fBzTP_3jjFQgMABeLTGtGfYU9?usp=sharing


File:RoofInsulationBox2.png|'''Roof Insulation Box v2.''' - FreeCAD - [[File:RoofInsulationBox2.FCStd]].
Vertical assembly simulation
File: https://drive.google.com/file/d/1mX8w3RzRHFxx48XEXSSdMaGa9ojHOana/view?usp=sharing


File:epdm.png|'''EPDM.''' - FreeCAD - [[File:epdm.fcstd]].
Folder (it's the wall modules assembly file): https://drive.google.com/drive/folders/1sRERDUL_lp9ukx1uFnxZNu26VTATVoJo?usp=sharing


File:roofangle.png|'''Roof angle for roof is 1.2 Degrees.''' - FreeCAD - [[File:Roofangle.fcstd]].
===Concept / Changes from v2===


File:RoofRiserAssembly.png|'''Roof Riser Assembly''' - FreeCAD - [[File:RoofRiserAssembly.fcstd]].
<html><iframe width="560" height="315" src="https://www.youtube.com/embed/X0-7CnqN7H8?start=398" title="YouTube video player" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture" allowfullscreen></iframe></html>


File:Roof_OSB.png|"Roof OSB"- FreeCAD - [[File:Roof_OSB.FCStd]].
===v3 update===


</gallery>
{{Hint|These modules now have a single center stud instead of two studs at 16" centers}}


=Walls=
===Modules in FreeCab===
<gallery perrow=6>


File:diysip.png|'''Seed Eco-Home 3 Wall Module.''' First Floor. - FreeCAD -[[File:diysip.FCStd]]
These wall panels use 10' OSB on the exterior. The OSB is offset 0.75" to the left and 1" down on each panel to help align the panel sides, sill, and top plate during installation. The interior side has small temporary tabs of 4" x 4" OSB added to assist with alignment.
 
</gallery>


<gallery perrow=6>
<gallery perrow=6>
Line 37: Line 36:


File:seh3-short_right_corner.png|'''Short Right Corner'''<br/>FreeCAD Detail-<br/>[[File:seh3_short_right_corner.FCStd]]<br/>FreeCAD Simple-<br/>[[File:seh3_short_right_corner-simple.FCStd]]
File:seh3-short_right_corner.png|'''Short Right Corner'''<br/>FreeCAD Detail-<br/>[[File:seh3_short_right_corner.FCStd]]<br/>FreeCAD Simple-<br/>[[File:seh3_short_right_corner-simple.FCStd]]
File:seh3-window.png|'''Window Panel'''<br/>FreeCAD Detail-<br/>[[File:seh3_small_window.FCStd]]<br/>FreeCAD Simple-<br/>[[File:seh3_small_window-simple.FCStd]]


File:seh3-example.png|'''Example'''<br/>FreeCAD Detail-<br/>[[File:seh3_example.FCStd]]
File:seh3-example.png|'''Example'''<br/>FreeCAD Detail-<br/>[[File:seh3_example.FCStd]]
Line 42: Line 43:


</gallery>
</gallery>
=Roof=
<gallery>
File:roofassyv3.png|'''Second Story Roof Assembly.''' Includes joists, OSB, Insulation Box, Insulation, EPDM - FreeCAD - [[File:SecondStoryRoofv3.fcstd]].
File:Roofjoists.png|'''Roof Joists.''' - FreeCAD - [[File:roofjoists.fcstd]].
File:Roofjoistlocking.png|'''Roof Joist Blocking.''' - FreeCAD - [[File:roofjoistblocking.fcstd]].
File:RoofInsulationBox2.png|'''Roof Insulation Box v2.''' - FreeCAD - [[File:RoofInsulationBox2.FCStd]].
File:insu.png|'''Rigid Insulation.''' - FreeCAD - [[File:rigidinsulation.fcstd]].
File:epdm.png|'''EPDM.''' - FreeCAD - [[File:epdm.fcstd]].
File:roofangle.png|'''Roof angle for roof is 1.2 Degrees.''' - FreeCAD - [[File:Roofangle.fcstd]].
File:RoofRiserAssembly.png|'''Roof Riser Assembly''' - FreeCAD - [[File:RoofRiserAssembly.fcstd]].
File:Roof_OSB.png|"Roof OSB"- FreeCAD - [[File:Roof_OSB.FCStd]].
</gallery>
[[Category: Seed Eco-Home]]

Latest revision as of 00:57, 6 January 2022


Updated Walls

Updated wall modules https://drive.google.com/drive/folders/1g7LEFEEsaIRU5bAUBurge6YieXr0s1pV?usp=sharing

1st story all assembly (some details on the modules are outdated, do not use these as reference to build modules, only for assembly purposes) https://drive.google.com/drive/folders/1Lp3ILl0fBzTP_3jjFQgMABeLTGtGfYU9?usp=sharing

Vertical assembly simulation File: https://drive.google.com/file/d/1mX8w3RzRHFxx48XEXSSdMaGa9ojHOana/view?usp=sharing

Folder (it's the wall modules assembly file): https://drive.google.com/drive/folders/1sRERDUL_lp9ukx1uFnxZNu26VTATVoJo?usp=sharing

Concept / Changes from v2

v3 update

Error creating thumbnail: File missing
Hint: These modules now have a single center stud instead of two studs at 16" centers

Modules in FreeCab

These wall panels use 10' OSB on the exterior. The OSB is offset 0.75" to the left and 1" down on each panel to help align the panel sides, sill, and top plate during installation. The interior side has small temporary tabs of 4" x 4" OSB added to assist with alignment.

Roof