Dairy Milker/Research Development: Difference between revisions
Jump to navigation
Jump to search
Line 51: | Line 51: | ||
===Vacuum System=== | ===Vacuum System=== | ||
*'''Vacuum Gauge''' | |||
**Placed inline with the pulsation lines and also between the vacuum reserve tank and vacuum regulator | |||
**Measures vacuum pressure | |||
**2 ports | |||
*'''Vacuum Reserve Tank''' | |||
**Distributes vacuum to the pulsation header lines and milk header line | |||
**Buffers the vacuum level for when air enters the vacuum system | |||
**1 port for milk header line | |||
**2 ports for pulsation header lines | |||
**1 port for main vacuum supply line | |||
*'''Vacuum Pump Filter''' | |||
**Prevents particulates from entering the vacuum pump | |||
**1 port for intake to main vacuum supply line | |||
**1 port for outtake to line to vacuum pump | |||
*'''Vacuum Pump''' | |||
**Applies a partial vacuum in the system | |||
**1 external port | |||
**1 vacuum port | |||
*'''Vacuum Regulator''' | |||
**Prevents vacuum level from increasing excessively by allowing air into the vacuum system when the vacuum level reaches a preset value | |||
**1 external port | |||
**2 inline ports | |||
*'''Vacuum Relief Valve''' | |||
**Prevents vacuum level from increasing excessively by allowing air into the vacuum system when the vacuum level reaches a preset value in case the vacuum regulator fails | |||
**1 external port | |||
**2 inline ports | |||
*'''Sanitary Trap''' | |||
**Separates the air-only vacuum system from the milk collection system | |||
**Prevents liquid and particulates from the milk collection system entering the vacuum system | |||
**1 port to vacuum system | |||
**1 port to collection system | |||
===Collection System=== | ===Collection System=== |
Revision as of 18:34, 6 September 2011
Dairy Milker | ||
---|---|---|
Home | Research & Development | Bill of Materials | Manufacturing Instructions | User's Manual | User Reviews | ![]() |
Research
Wanted: Brief description about the highest version of the GVCSTool
Theory
Wanted: Brief paragraph regarding the reasoning behind adding this tool to the GVCS
Relevant Links
Conceptual Notes
Wanted: Ifs, ands and buts.
Development
Overview
- The Dairy Milker is comprised of 3 major systems:
- Milking Unit
- Vacuum System
- Collection System
- See page 8 of link "Milk and Milking" for a full diagram
Milking Unit
- Includes the pulsator, teatcups, short and long milk tubes, short and long pulse tubes, and the claw.
- Claw
- 1 port for the long milk tube
- 4 ports for the short milk tubes
- 1 port for the long pulsation tube
- 4 ports for the short pulse tubes
- Teatcup
- Metal or hard plastic teat cup shell attached to a flexible rubber or synthetic teat cup liner
- Space between the teat cup shell and teat cup liner is called the pulsation chamber
- 1 port for the short milk tube
- 1 port for the short pulsation tube
- Pulsator
- Small machine that alternates between applying vacuum at the teatcups and admitting air at atmospheric pressure to the teatcups
- 1 port for stall cock
- 1 port for long pulse tube
Vacuum System
- Vacuum Gauge
- Placed inline with the pulsation lines and also between the vacuum reserve tank and vacuum regulator
- Measures vacuum pressure
- 2 ports
- Vacuum Reserve Tank
- Distributes vacuum to the pulsation header lines and milk header line
- Buffers the vacuum level for when air enters the vacuum system
- 1 port for milk header line
- 2 ports for pulsation header lines
- 1 port for main vacuum supply line
- Vacuum Pump Filter
- Prevents particulates from entering the vacuum pump
- 1 port for intake to main vacuum supply line
- 1 port for outtake to line to vacuum pump
- Vacuum Pump
- Applies a partial vacuum in the system
- 1 external port
- 1 vacuum port
- Vacuum Regulator
- Prevents vacuum level from increasing excessively by allowing air into the vacuum system when the vacuum level reaches a preset value
- 1 external port
- 2 inline ports
- Vacuum Relief Valve
- Prevents vacuum level from increasing excessively by allowing air into the vacuum system when the vacuum level reaches a preset value in case the vacuum regulator fails
- 1 external port
- 2 inline ports
- Sanitary Trap
- Separates the air-only vacuum system from the milk collection system
- Prevents liquid and particulates from the milk collection system entering the vacuum system
- 1 port to vacuum system
- 1 port to collection system
Collection System
Design
- Requirements
- Speed
- Throughput
- Weight
- Size Constraints
- Feed stock
- Design Description
- Calculations
- Drawings and Diagrams
- Concept and Alternatives
- Full Design Views
- Cut-away Views
- Exploded Parts View
- 3D Renders
- Decisions
- Project Team
Industry Standards
Industry Standard | GVCSTool |
---|
Funding
Wanted: List of expenses for prototyping and documenting GVCSTool
Peer Reviews
Wanted: Peer reviews from the scientific community regarding the R&D of GVCSTool
Experiments and Prototypes
Wanted: Empirical data on performance