 (Created page with "*Allow for 9 feet of flex from the top of stack vent so pipe has up to 2" of flex over the distance and thus can be prebuilt. *Are rubber couplers allowed? *Cap the top for ex...")  | 
				No edit summary  | 
				||
| (7 intermediate revisions by the same user not shown) | |||
| Line 2: | Line 2: | ||
*Are rubber couplers allowed?  | *Are rubber couplers allowed?  | ||
*Cap the top for extension to upper bathroom  | *Cap the top for extension to upper bathroom  | ||
*Frame Panel 1 flat so there is sufficient space for a 3" vent stack, not 4"  | *Frame Panel 1 flat so there is sufficient space for a 3" vent stack, not 4". Meaning 4" space exists if flat 2x4s are used  | ||
*Or use island framing, where studs are no t continuous but only islands  | |||
*3" vent so ack is desirable, so we can go thru framing. OD is 3.5 leaving 1" on each side.  | |||
*Second floor toilet pre-plumb leaves from the top of Panel 1, and bends towards 2nd floor toilet sweep. Latch door is pre-set in 2nd floor prior to vinyl floor. Location is digitized, so this is replicable.  | |||
*Vent stack is above 2nd floor soil stack tee, where tee is 3-3-1.5' sweep. Vent is 2" or 1.5". 2" makes it extra unique part, to be avoided.  | |||
Latest revision as of 22:44, 14 March 2021
- Allow for 9 feet of flex from the top of stack vent so pipe has up to 2" of flex over the distance and thus can be prebuilt.
 - Are rubber couplers allowed?
 - Cap the top for extension to upper bathroom
 - Frame Panel 1 flat so there is sufficient space for a 3" vent stack, not 4". Meaning 4" space exists if flat 2x4s are used
 - Or use island framing, where studs are no t continuous but only islands
 - 3" vent so ack is desirable, so we can go thru framing. OD is 3.5 leaving 1" on each side.
 - Second floor toilet pre-plumb leaves from the top of Panel 1, and bends towards 2nd floor toilet sweep. Latch door is pre-set in 2nd floor prior to vinyl floor. Location is digitized, so this is replicable.
 - Vent stack is above 2nd floor soil stack tee, where tee is 3-3-1.5' sweep. Vent is 2" or 1.5". 2" makes it extra unique part, to be avoided.