Open Source Helical Piers Design Guide: Difference between revisions

From Open Source Ecology
Jump to navigation Jump to search
Line 9: Line 9:
*'''2-7/8"''': Steel shaft at 2-7/8" diameter and .217 wall has about 1.8 sq in of area according to [[Area Calculator]]. J55 alloy at 55ksi means that ultimate compressive load with 0 margin of safety (see [[Factor of Safety]]) is about 100k lb.
*'''2-7/8"''': Steel shaft at 2-7/8" diameter and .217 wall has about 1.8 sq in of area according to [[Area Calculator]]. J55 alloy at 55ksi means that ultimate compressive load with 0 margin of safety (see [[Factor of Safety]]) is about 100k lb.
*'''2-3/8"''': Steel shaft at 2-3/8" diameter and .156 wall has about 1.1 sq in of area according to [[Area Calculator]]. J55 alloy at 55ksi means that ultimate compressive load is 60 klb.
*'''2-3/8"''': Steel shaft at 2-3/8" diameter and .156 wall has about 1.1 sq in of area according to [[Area Calculator]]. J55 alloy at 55ksi means that ultimate compressive load is 60 klb.
*Safety factor of 2: 30k lb.
*Safety factor of 4-6 [https://www.engineeringtoolbox.com/factors-safety-fos-d_1624.html] - 10-15 klb allowed load.


=Links=
=Links=
*[[Open Source Helical Piers]]
*[[Open Source Helical Piers]]

Revision as of 17:06, 19 September 2020

Composition

  • Connector Fitting and pin
  • Flighting
  • Shaft

Shaft First Principle Calculations

  • 2-7/8": Steel shaft at 2-7/8" diameter and .217 wall has about 1.8 sq in of area according to Area Calculator. J55 alloy at 55ksi means that ultimate compressive load with 0 margin of safety (see Factor of Safety) is about 100k lb.
  • 2-3/8": Steel shaft at 2-3/8" diameter and .156 wall has about 1.1 sq in of area according to Area Calculator. J55 alloy at 55ksi means that ultimate compressive load is 60 klb.
  • Safety factor of 4-6 [1] - 10-15 klb allowed load.